RevMed
Home/Specialty/Cardiovascular/Oxygenator, Long Term Support Greater Than 6 Hours

Oxygenator, Long Term Support Greater Than 6 Hours

9 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
MC3 Nautilus(tm) ECMO Oxygenator
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Nautilus ECMO oxygenators are diffusion membrane oxygenators used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Blood enters the device and passes through both the heat exchange membrane, where temperature is adjusted, and the gas transfer membrane, where oxygen is added and carbon dioxide is removed.
0
-
MC3 Nautilus (tm) Smart ECMO Module
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Nautilus ECMO oxygenators are diffusion membrane oxygenators used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Blood enters the device and passes through both the heat exchange membrane, where temperature is adjusted, and the gas transfer membrane, where oxygen is added and carbon dioxide is removed. Smart ECMO Module device contains integrated sensors with an electronic touch screen display. The following measured parameters are visible on the electronic display: inlet pressure, inlet oxygen saturation, outlet pressure, outlet oxygen saturation, and outlet blood temperature.
0
-
MC3 Nautilus Power Cord NEMA
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Power Cord (NEMA 5-5, 5m) for Nautilus Smart ECMO Module
0
-
MC3 Nautilus(tm) Smart Power Supply 12VDC
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
12V power supply component for the Nautilus(tm) Smart ECMO Module
0
-
MC3 Nautilus(tm) Smart Power Supply 12VDC
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
12V power supply component for the Nautilus(tm) Smart ECMO Module This is the power supply accessory for 48135/48135E Nautilus Smart ECMO Module
0
-
MC3 Nautilus ECMO Oxygenator
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Nautilus ECMO oxygenators are diffusion membrane oxygenators used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Blood enters the device and passes through both the heat exchange membrane, where temperature is adjusted, and the gas transfer membrane, where oxygen is added and carbon dioxide is removed.
0
-
MC3 Nautilus Smart ECMO Module
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Nautilus ECMO oxygenators are diffusion membrane oxygenators used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Blood enters the device and passes through both the heat exchange membrane, where temperature is adjusted, and the gas transfer membrane, where oxygen is added and carbon dioxide is removed. Smart ECMO Module device contains integrated sensors with an electronic touch screen display. The following measured parameters are visible on the electronic display: inlet pressure, inlet oxygen saturation, outlet pressure, outlet oxygen saturation, and outlet blood temperature.
0
-
Nautilus VF Oxygenator Cable
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Power and data cable for the Nautilus VF ECMO Oxygenator
0
-
Nautilus VF ECMO Oxygentaor
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
The Nautilus VF ECMO Oxygenator is a diffusion polymethylpentene (PMP) membrane oxygenator with BalanceTM Biosurface used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Blood enters the device and passes through both the heat exchange membrane, where temperature is adjusted, and the gas transfer membrane, where oxygen is added and carbon dioxide is removed. The device contains integrated sensors. The following measured parameters can be transmitted to the VitalFlow ECMO Console through the Nautilus VF Oxygenator Cable: inlet pressure, inlet oxygen saturation, outlet pressure, outlet oxygen saturation, and outlet blood temperature. The difference between the inlet and outlet pressure, delta pressure, is calculated and also transmitted.