RevMed
Home/Specialty/Anesthesiology

Anesthesiology

133,530 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Available
Starting At
Name
Company Name
Description
0
-
BE 142
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 142 is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%. Objectives of PEEP therapy: 1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,2) aid in the prevention of atelectasis via aveolar stinting, 3) decrease in the inspired oxygen fraction (FiO2) is an advantage, 4) help in the stabilization of flail chest condition, and 5) monitor tidal volume by connecting a spirometer to the outlet port.
0
-
BE 139-105 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 15mm O.D. x 15mm I.D./22mm O.D. Molded of polycarbonate. Reusable.
0
-
BE 139 Pressure Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 139 Pressure Adapter: Dimensions - Barbed port fits 3/16" I.D. tubing x 15mm I.D./22mm O.D. x 15mm O/D.
0
-
BE 131 One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 131 One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.The device includes a silicone rubber connector with 22mm I.D. Inlet.
0
-
BE 130-23BB One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130-23BB One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 130-22B One-way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130-22B One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 130 One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130 One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 127-7.5-40 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-7.5-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port, (1) 7.5mm ID temperature probe port, and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127-7.5 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-7.5 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and 7.5mm temperature probe port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127-40 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127 Wye Connector with (2) 22mm OD ports and (1) 15mm ID/22mm OD port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 125-1TD Disposable Tee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1TD Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Can be used to easily add a monitoring device such as a temperature probe to the breathing circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D. Single Patient Use. Molded of High Density Polyethylene.
0
-
BE 125-1T ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1T Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D./22mm O.D Reusable.
0
-
BE 125-1 ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm O.D. x 15mm I.D./22mm O.D Reusable.
0
-
BE 125 ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 15mm I.D./22mm O.D. x 15mm O.D./22mm O.D Reusable.
0
-
BE 122-30 Flexible Support Arm
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-30 Flexible Support Arm - 30" - (With extension, reaches 44" total length) - Use to support ventilator tubing; Rotates up to 360° and can be locked in place. Adapts to most ventilators by using Flexible Support Arm Brackets. Ventilator tubing is held in place with Flexible Support Arm Tubing Clamps mounted to the Flexible Support Arm. All are manufactured in the USA by Instrumentation Industries, Inc.
0
-
"BE 122-2TSB - 4"" Flexible Support Arm Double Tubing Clamp"
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-2TSB - 4" Flexible Support Arm Double Tubing Clamp holds two ventilator tubes in place when attached to an III "Flexible Support Arm". Made of polypropylene and anodized aluminum with phenolic ball knob. Made in the USA.
0
-
"BE 122-2TB - 8"" Flexible Support Arm Double Tubing Clamp"
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-2TB - 8" Flexible Support Arm Double Tubing Clamp holds two ventilator tubes in place when attached to an III "Flexible Support Arm". Made of polypropylene and anodized aluminum with phenolic ball knob. Made in the USA.
0
-
BE 122-24 Flexible Support Arm
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-24 Flexible Support Arm - 24" - (With extension, reaches 38" total length) - Use to support ventilator tubing; Rotates up to 360° and can be locked in place. Adapts to most ventilators by using Flexible Support Arm Brackets. Ventilator tubing is held in place with Flexible Support Arm Tubing Clamps mounted to the Flexible Support Arm. All are manufactured in the USA by Instrumentation Industries, Inc.
0
-
BE 120-AKW 45 degree Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Specialty Adapter - 22mm ID x 22mm OD Adapter for ventilator circuits/CPAP systems. Molded of polystyrene butadiene. Single Patient Use.
0
-
BE 120-22D Mouthpiece Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Specialty Mouthpiece Adapter with 22mm ID fitting. Molded of polystyrene butadiene. Single Patient Use.
0
-
BE 117-W Disposable Tee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 117-W Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Can be used to easily add a monitoring device such as a temperature probe to the breathing circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D./22mm O.D. Single Patient Use. Molded of High Density Polyethylene.
0
-
BE 117 Non-Rebreathing Tee Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 117 Non-Rebreathing ‘T’ is designed for use with a spontaneously breathing patient where “back flow” must be avoided. The ‘T’ is designed to prevent the flow of gas back toward the source and to ensure unilateral breathing.
0
-
BE114-5TB Flexible Support Arm Single Tubing Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE114-5TB Flexible Support Arm Single Tubing Clamp holds a ventilator tube in place when attached to an III "Flexible Support Arm". Made of polypropylene with phenolic ball knob mount. Made in the USA.
0
-
BE 114-5 Flexible Support Arm Universal Rail Mount Bracket
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 114-5 Flexible Support Arm Universal Rail Mount Bracket permits rail mounting of "Flexible Support Arms". The BE 114-5 is not compatible with rails mounted flush to wall. Components and materials: bracket body: anodized aluminum; screw: steel with phenolic knob. Made in the USA.
0
-
BE 114-2 Flexible Support Arm Pole Bracket
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 114-2 Flexible Support Arm Pole Bracket permits mounting of "Flexible Support Arms" to poles up to 1.5" in diameter. Components and materials: bracket body: anodized aluminum; screw: steel with phenolic handle. Made in the USA.
0
-
BE 114-1 Flexible Support Arm Pole Bracket
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 114-1 Flexible Support Arm Pole Bracket permits mounting of "Flexible Support Arms" to poles up to 1" in diameter. Components and materials: bracket body: anodized aluminum; screw: steel with phenolic handle. Made in the USA.
0
-
BE 106 Adult Adapter with Vent
INSTRUMENTATION INDUSTRIES, INCORPORATED
Specialty Adapter with Vent - 15mm ID/22mm OD/15mm ID/22mm OD. Fits components of adult ventilator circuits. Molded of polycarbonate. Reusable.
0
-
BE 105-8 Bronchoscope Swivel
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 105-8 Bronchoscope Swivel - 15mm ID/22mm OD (patient port) x15mm OD (equipment port). Reusable. Fits components of adult ventilator circuits. Molded of polyetherimide. Includes two silicone rubber caps; one cap allows for the use of a suctioning catheter while the other cap allows for the use of a fiber-optic bronchoscope without significant loss of PEEP.
0
-
BE 105-7 Bronchoscope Swivel
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 105-7 Bronchoscope Swivel - 15mm ID (patient port) x15mm OD (equipment port). Reusable. Fits components of adult ventilator circuits. Molded of polyetherimide. Includes two silicone rubber caps; one cap allows for the use of a suctioning catheter while the other cap allows for the use of a fiber-optic bronchoscope without significant loss of PEEP.
0
-
BE 105-40 Pressure Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 105-40 Pressure Adapter: Dimensions - Barbed port fits 3/16" I.D. tubing, x 15mm I.D./22mm O.D. x 15mm I.D./22mm O.D. Barbed port is capped with a silicone rubber cap.
0
-
BE 105-2X22D Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polystyrene butadiene, Single Patient Use.
0
-
BE 105-2X22 Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
General Adapter - 22mm ID x 22mm ID adapter for use in breathing/ventilator circuit. Molded of polycarbonate. Reusable.
0
-
BE 105-2222 Swivel Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Swivel Adapter 22mm ID x 15mm ID/22mm OD. Specialty adapter for ventilator circuits/CPAP systems. Swivels 360 degrees. Molded of polypropylene. Single Patient Use.
0
-
BE 105-101-40 Pressure Adapter with Silicone Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 105-101-40 Pressure Adapter with Connector: Dimensions - Barbed port fits 3/16" I.D. tubing x 15mm I.D./22mm O.D. x 22mm I/D (silicone connector end) . Barbed port is capped with a silicone rubber cap.
0
-
BE 102 Swivel Tubing Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
Ventilator Tubing Accessory - Swivel Tubing Clamp. Swivels 360 degrees; fits tubing and rails 1/2" to 1" inch diameter.
0
-
BE 101-00-3443 Straight Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Connector - 22mm ID x 22mm ID. Fits components of adult ventilator circuits. Molded of silicone rubber. Reusable.
0
-
BE 101-00-1426 Tapered Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
Tapered Connector - 22mm ID x 27mm ID. Fits components of adult ventilator circuits. Molded of silicone rubber. Reusable.
0
-
BE 1000-2 O2 Instant Flow Valve Bag Hanger
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 1000-2 Bag Hanger mates with arm of O2 Instant Flow Valve to support a resuscitation bag. This is an accessory to the BE 3000 Series Oxygen Instant Flow Valves. Reusable.
0
-
BB 4500-20D Mask/Filter Storage Box
INSTRUMENTATION INDUSTRIES, INCORPORATED
Wall-mounted storage box provides storage and immediate availability for emergency-use items such as oxygen masks, resuscitator bags, airways, masks, filters, etc. (The storage box does not include these items.) Dimensions: 20" Length x 8" Width x 6" Depth.
0
-
AM MIL-4 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 4 - 205mm
0
-
AM MIL-3 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 3 - 195mm
0
-
AM MIL-2 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 2 - 155mm
0
-
AM MIL-1.5 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 1.5 - 127mm
0
-
AM MIL-1 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 1 - 102mm
0
-
AM MIL-0 Miller Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Straight Miller laryngoscope blade Size 0 - 75mm
0
-
AM MAC-4 Macintosh Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Curved Macintosh laryngoscope blade Size 4 - 158mm
0
-
AM MAC-3 Macintosh Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Curved Macintosh laryngoscope blade Size 3 - 130mm
0
-
AM MAC-2 Macintosh Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Curved Macintosh laryngoscope blade Size 2 - 108mm
0
-
AM MAC-1 Macintosh Blade
INSTRUMENTATION INDUSTRIES, INCORPORATED
Curved Macintosh laryngoscope blade Size 1 - 87mm