RevMed
Home/Brands/ABAXIS, INC.

ABAXIS, INC.

19 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Available
Starting At
Name
Company Name
Description
0
-
Piccolo AmLyte 13
ABAXIS, INC.
The Piccolo® AmLyte 13 , used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, amylase, aspartate aminotransferase (AST), calcium, c-reactive protein (CRP), creatine kinase, creatinine, glucose, potassium, sodium, total bilirubin and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
0
-
Piccolo MetLac 12 Panel
ABAXIS, INC.
The Piccolo® MetLac 12 Panel reagent disc, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of albumin, calcium, chloride, creatinine, glucose, lactate, magnesium, phosphorus, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in lithium heparinized whole blood or lithium heparinized plasma in a clinical laboratory setting or point-of-care location.
0
-
Piccolo BioChemistry Panel Plus
ABAXIS, INC.
The Piccolo® BioChemistry Panel Plus, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), c-reactive protein (CRP), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total protein, blood urea nitrogen (BUN), and uric acid in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
0
-
Piccolo MetLyte Plus CRP
ABAXIS, INC.
The Piccolo® MetLyte Plus CRP reagent disc, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of c-reactive protein (CRP), chloride, creatine kinase, creatinine, glucose, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. The Abaxis CRP method is not intended for high sensitivity CRP measurement.
0
-
Piccolo Kidney Check
ABAXIS, INC.
The Piccolo® Kidney Check , used with the Piccolo Xpress chemistry analyzer, is intended to be used for the in vitro quantitative determination of creatinine and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Basic Metabolic Panel Plus
ABAXIS, INC.
The Piccolo® Basic Metabolic Panel Plus, used with the Piccolo blood chemistry analyzer or Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of calcium, chloride, creatinine, glucose, lactate dehydrogenase, magnesium, potassium, sodium, total carbon dioxide, and blood urea nitrogen in a clinical laboratory setting or point-of-care location. This disc is for testing heparinized plasma and serum, only.
0
-
Piccolo Lipid Panel Plus
ABAXIS, INC.
The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), triglycerides (TRIG), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and glucose (GLU) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From the CHOL, HDL and TRIG determinations, low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo General Chemistry 13
ABAXIS, INC.
The Piccolo® General Chemistry 13 used with the Piccolo blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), amylase, aspartate aminotransferase (AST), calcium, creatinine, gamma glutamyltransferase (GGT), glucose, total bilirubin, total protein, blood urea nitrogen (BUN), and uric acid in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Comprehensive Metabolic Panel
ABAXIS, INC.
The Piccolo® Comprehensive Metabolic Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), albumin, alkaline phosphatase (ALP), aspartate aminotransferase (AST), calcium, chloride, creatinine, glucose, potassium, sodium, total bilirubin, total carbon dioxide, total protein, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Renal Function Panel
ABAXIS, INC.
The Piccolo® Renal Function Panel, used with the Piccolo® blood chemistry analyzer or the PiccoloXpress® chemistry analyzer is intended to be used for the in vitro quantitative determination of albumin, calcium, chloride, creatinine, glucose, phosphorus, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Hepatic Function Panel
ABAXIS, INC.
The Piccolo® Hepatic Function Panel, used with the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitroquantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, aspartate aminotransferase, directbilirubin, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratorysetting or point-of-care location.
0
-
Piccolo Lipid Panel
ABAXIS, INC.
The Piccolo® Lipid Panel reagent disc, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® Chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), and triglycerides (TRIG) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From these determinations low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer.Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders.This test is waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the test is considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Basic Metabolic Panel
ABAXIS, INC.
The Piccolo® Basic Metabolic Panel, used with the Piccolo blood chemistry analyzer or the PiccoloXpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of calcium, chloride, creatinine, glucose, potassium, sodium, total carbon dioxide, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo MetLyte 8 Panel
ABAXIS, INC.
The Piccolo® MetLyte 8 Panel, used with the Piccolo® blood chemistry analyzer or the PiccoloXpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of chloride, creatine kinase, creatinine, glucose, potassium, sodium, total carbon dioxide and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Electrolyte Panel
ABAXIS, INC.
The Piccolo® Electrolyte Panel, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of chloride, potassium, sodium, and total carbon dioxide in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo General Chemistry 6
ABAXIS, INC.
The Piccolo® General Chemistry 6 , used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended to be used for the in vitro quantitative determination of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine, gamma glutamyltransferase (GGT), glucose, and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Liver Panel Plus
ABAXIS, INC.
The Piccolo® Liver Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, utilizes dry and liquid reagents to provide in vitro quantitative determinations of alanine aminotransferase, albumin, alkaline phosphatase, amylase, aspartate aminotransferase, gamma glutamyltransferase, total bilirubin, and total protein in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
0
-
Piccolo Xpress Military Deployment Kit
ABAXIS, INC.
The Piccolo Xpress chemistry analyzer provides quantitative in-vitro determinations of clinical chemistry analytes in lithium-heparinized whole blood, heparinized plasma, or serum. This kit contains additional accessories for supporting US military requirements.The Piccolo Xpress is a portable clinical chemistry system designed for accurate, on-site patient testing. It allows healthcare practitioners to perform routine multi-chemistry panels using 0.1cc of whole blood, serum or plasma. The system uses patented single-use reagent discs which contain up to 14 chemistry tests.Simply pipette the sample into the disc, insert the disc into the analyzer and results are printed or transferred to an LIS/EMR in about 12 minutes. No operator intervention is required. The Piccolo Xpress employs on-board continuous intelligent Quality Control (iQC®) to monitor the analyzer, reagent reactions and sample to ensure the highest quality and accuracy in results.
0
-
Piccolo Xpress
ABAXIS, INC.
The Piccolo Xpress chemistry analyzer provides quantitative in-vitro determinations of clinical chemistry analytes in lithium-heparinized whole blood, heparinized plasma, or serum.The Piccolo Xpress is a portable clinical chemistry system designed for accurate, on-site patient testing. It allows healthcare practitioners to perform routine multi-chemistry panels using 0.1cc of whole blood, serum or plasma. The system uses patented single-use reagent discs which contain up to 14 chemistry tests.Simply pipette the sample into the disc, insert the disc into the analyzer and results are printed or transferred to an LIS/EMR in about 12 minutes. No operator intervention is required. The Piccolo Xpress employs on-board continuous intelligent Quality Control (iQC®) to monitor the analyzer, reagent reactions and sample to ensure the highest quality and accuracy in results.