Gramedica
Main Filters
Gramedica
Gramedica | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
CarryingCase | 0 | - | ||
CarryingCase2 | 0 | - | ||
CP15-05-FG | 0 | - | ||
CP15-06-FG | 0 | - | ||
CP15-07-FG | 0 | - | ||
CP15-08-FG | 0 | - | ||
CP15-09-FG | 0 | - | ||
CP15-10-FG | 0 | - | ||
GM-150-01 | 0 | - | ||
GM-150-02 | 0 | - | ||
GM-150-03 | 0 | - | ||
GM-150-04 | 0 | - | ||
GM-160-01 | 0 | - | ||
GM-160-03 | 0 | - | ||
GM-160-04 | 0 | - | ||
GM-501-00 | 0 | - | ||
GM-501-02 | 0 | - | ||
GM-501-04 | 0 | - | ||
GM-501-06 | 0 | - | ||
GM-501-08 | 0 | - | ||
GM-501-10 | 0 | - | ||
GM-503-00 | 0 | - | ||
GM-503-03 | 0 | - | ||
GM-503-06 | 0 | - | ||
GM-503-09 | 0 | - | ||
GM-503-12 | 0 | - | ||
GM-503-15 | 0 | - | ||
GM-503-18 | 0 | - | ||
GM-503-21 | 0 | - | ||
GM-503-24 | 0 | - | ||
GM-503-27 | 0 | - | ||
GM-503-30 | 0 | - | ||
GM-504-03 | 0 | - | ||
GM-504-06 | 0 | - | ||
GM-504-09 | 0 | - | ||
GM-504-12 | 0 | - | ||
GM-504-15 | 0 | - | ||
GM-504-18 | 0 | - | ||
GM-504-21 | 0 | - | ||
GM-504-24 | 0 | - | ||
GM-504-27 | 0 | - | ||
GM-504-30 | 0 | - | ||
GM-DS-LL | 0 | - |
93 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
Graham Decompression Scissors, Curved Left
Gramedica
Reusable Graham Decompression Scissors, curved left, for cutting soft tissue.
0
-
osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 18 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Large
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 30 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 27 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 24 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 21 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 18 Degree Angulated Bone Plate Implant-Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 15 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 12 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 9 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 6 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 3 Degree Angulated Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 0 Degree, Flat Bone Plate Implant, Small
Gramedica
The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 10mm
Gramedica
osteo-WEDGE Bone Plate 10mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 08mm
Gramedica
osteo-WEDGE Bone Plate 08mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 06mm
Gramedica
osteo-WEDGE Bone Plate 06mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 04mm
Gramedica
osteo-WEDGE Bone Plate 04mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 02mm
Gramedica
osteo-WEDGE Bone Plate 02mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Bone Plate 00mm
Gramedica
osteo-WEDGE Bone Plate 00mm. Non-sterile single use implant for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 Drill Guide
Gramedica
osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE2 Drill Guide
Gramedica
osteo-WEDGE2 Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Drill Guide
Gramedica
osteo-WEDGE Drill Guide, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Screw Retainer Sleeve
Gramedica
osteo-WEDGE Screw Retainer Sleeve, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Driver
Gramedica
osteo-WEDGE Driver, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Depth Gauge
Gramedica
osteo-WEDGE Depth Gauge, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Depth Gauge Sleeve
Gramedica
osteo-WEDGE Depth Gauge Sleeve, a reusable instrument, for use with the osteo-WEDGE Opening Wedge Bone Locking Plate System. The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
HyProCure Sizer 10
Gramedica
HyProCure Sizer 10. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
HyProCure Sizer 09
Gramedica
HyProCure Sizer 09. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
HyProCure Sizer 08
Gramedica
HyProCure Sizer 08. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
HyProCure Sizer 07
Gramedica
HyProCure Sizer 07. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
HyProCure Sizer 06
Gramedica
HyProCure Sizer 06. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
HyProCure Sizer 05
Gramedica
HyProCure Sizer 05. Reusable instrument, for use with the HyProCure Sinus Tarsi Implant System. Indications: HyProCure is a talotarsal stabilization device used in the treatment of talotarsal dislocation and resulting sequela. The implant is designed to stabilize the talus on the tarsal mechanism to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus on the tarsal mechanism, while allowing normal talotarsal joint motion.
0
-
osteo-WEDGE2 Open Wedge Bone Locking System
Gramedica
osteo-WEDGE2 Opening Wedge Bone Locking System -Kit (containing non-sterile single use implants (2.5mm locking bone screws, 3.0mm locking bone screws and bone plates), non-sterile single use temporary tacks and non-sterile reusable instruments). The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
0
-
osteo-WEDGE Opening Wedge Bone Locking System
Gramedica
osteo-WEDGE Opening Wedge Bone Locking System -Kit (containing non-sterile single use implants (2.5mm locking bone screws, 3.0mm locking bone screws and bone plates), non-sterile single use temporary tacks and non-sterile reusable instruments). The osteo-WEDGE Opening Wedge Bone Locking Plate System is used for adult and transitional adolescent (18 to 21 years old) patients for the purpose of stabilization and/or correction of angular deviations within an individual bone or in between two adjacent bones in the foot, such as opening wedge osteotomy for first metatarsal cuneiform joint deviations.
- 1
- 2