RevMed
Home/Brands/INTELESENS LIMITED

INTELESENS LIMITED

8 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
Aingeal
INTELESENS LIMITED
The Intelesens Aingeal is used to monitor and transmit physiological data to a remote application for display or analysis by a clinician. The device can be worn by ambulatory or non-ambulatory adult patients in a healthcare environment to support clinical staff when they are carrying out their routine observations or when a patient would otherwise be in an unmonitored or unobserved situation.This re-usable device is intend to be used on the patient for short term periods only.The device is intended to be used on adult patients for monitoring of ECG, respiration, heart rate, skin temperature and activity levels in a healthcare setting.The device can be used where information on ECG, respiration, heart rate, skin temperature, and activity levels would be useful.The device uses on-board ECG arrhythmia detection algorithms to automatically record and send ECG data if the user is suspected to be experiencing an arrhythmia event. The device transmits the data to the remote application at user defined intervals or upon the detection of an arrhythmia event (arrhythmia or threshold breach).
0
-
Zensor electrode
INTELESENS LIMITED
The zensor electrode array, electrocardiograph (ECG) and respiration electrode is a disposable, pre-gelled, self-adhesive, three lead electrode array, which is in contact with the patient's skin. The device is used in conjunction with the zensor device in order to monitor vital signs for ECG, respiration and motion for ambulatory and non-ambulatory patients in a home environment. This is a single use device and is intended to be used on an adult patient for a period of up to 6 days before a replacement is required.
0
-
ZENSOR
INTELESENS LIMITED
The zensor monitoring device is a small, lightweight, wearable, non-invasive, re-chargeable battery operated portable system connected to an electrode accessory (single-use disposable Intelesens zensor Electrode Array) which in turn is in contact with the patient’s body. The device is to be used in the patient’s home environment to provide clinicians with patient physiological data, while allowing for patient mobility. The zensor monitoring system provides full disclosure ECG and cardiac event monitoring for adult patients. The physiological parameters monitored include ECG and Respiration waveforms, Heart Rate and Respiration Rate, as well as lethal and high acuity arrhythmias (Asystole, Tachycardia, Ventricular Fibrillation, Bradycardia and Atrial Fibrillation). The zensor monitoring device has the option to store full disclosure ECG & Respiration data and/or wirelessly transmit pre-defined event alerts to the Intelesens zensoronline system for review by healthcare practitioners. All physiological data stored on the device can be downloaded for viewing on Intelesens zensor+ (Ambulatory ECG Full Disclosure ECG and Event Viewer) for later analysis by a clinician.
0
-
Zensor+ software
INTELESENS LIMITED
The zensor software system is a web and PC based tool assisting clinicians in managing patients being monitored with Intelesens' medical devices. The web and PC components of the software can be configured to be used individually or together.The zensor+ software allows review of all physiological data that has been previously stored and downloaded from the monitoring device for later analysis by a clinician.The system is intended to be used to obtain physiological readings for use in routine check-ups. Any events or variations in physiological readings are not intended to be used to summon emergency care.
0
-
Zensoronline software
INTELESENS LIMITED
The zensor software system is a web and PC based tool assisting clinicians in managing patients being monitored with Intelesens' medical devices. The web and PC components of the software can be configured to be used individually or together.The zensoronline software has the option to receive wirelessly transmitted pre-defined event alerts from the Intelesens' monitoring device for review by healthcare practitioners and/or review all physiological data that has been previously stored and downloaded from the monitoring device for later analysis by a clinician.The system is intended to be used to obtain physiological readings for use in routine check-ups. Any events or variations in physiological readings are not intended to be used to summon emergency care.
0
-
Aingeal 3-patch electrode
INTELESENS LIMITED
The Aingeal 3-Patch Electrode Array is an electrocardiograph (ECG), respiration and temperature electrode. It is a disposable, pre-gelled, self-adhesive, single lead electrode array, which is designed to be used in contact with the patient’s skin. The device is used in conjunction with the Aingeal Device in order to monitor vital signs for ECG, respiration, motion and temperature for ambulatory and non-ambulatory patients in a hospital environment.This is a single use device and is intended to be used on an adult patient for a period of up to 72 hours before a replacement is required.
0
-
Zensor electrode
INTELESENS LIMITED
The zensor electrode array, electrocardiograph (ECG) and respiration electrode is a disposable, pre-gelled, self-adhesive, three lead electrode array, which is in contact with the patient's skin. The device is used in conjunction with the zensor device in order to monitor vital signs for ECG, respiration and motion for ambulatory and non-ambulatory patients in a home environment. This is a single use device and is intended to be used on an adult patient for a period of up to 72 hours before a replacement is required.
0
-
ZENSOR
INTELESENS LIMITED
The zensor monitoring device is a small, lightweight, wearable, non-invasive, re-chargeable battery operated portable system connected to an electrode accessory (single-use disposable Intelesens zensor Electrode Array) which in turn is in contact with the patient’s body. The device is to be used in the patient’s home environment to provide clinicians with patient physiological data, while allowing for patient mobility. The zensor monitoring system provides full disclosure ECG and cardiac event monitoring for adult patients. The physiological parameters monitored include ECG and Respiration waveforms, Heart Rate and Respiration Rate, as well as lethal and high acuity arrhythmias (Asystole, Tachycardia, Ventricular Fibrillation, Bradycardia and Atrial Fibrillation). The zensor monitoring device has the option to store full disclosure ECG & Respiration data and/or wirelessly transmit pre-defined event alerts to the Intelesens zensoronline system for review by healthcare practitioners. All physiological data stored on the device can be downloaded for viewing on Intelesens zensor+ (Ambulatory ECG Full Disclosure ECG and Event Viewer) for later analysis by a clinician.