RevMed
Home/Brands/MPS Micro Precision Systems AG

MPS Micro Precision Systems AG

303 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Available
Starting At
Name
Company Name
Description
0
-
Acetabular reamer Ø43 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø42 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø41 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø40 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø39 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø38 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø37 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Acetabular reamer Ø36 with round tooth
MPS Micro Precision Systems AG
Acetabular reamer for hip arthroplasty
0
-
Femoral IM reamer Ø8.5 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø7 x 475 mm, can. Ø3.1 mm Stryker/Zimmer-Hall coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø16 x 483 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø15.5 x 483 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø15 x 483 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø14.5 x 483 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø14 x 482 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø13.5 x 482 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø13 x 482 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø12.5 x 480 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø12 x 480 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø11.5 x 480 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø11 x 478 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø10.5 x 478 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø10 x 477 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø9.5 x 477 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø9 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø9 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8.5 x 475 mm, can. Ø3.1 mm Hudson coup..
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8.5 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø8 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø7.5 x 475 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
Femoral IM reamer Ø7 x 474 mm, can. Ø3.1 mm Hudson coup.
MPS Micro Precision Systems AG
Femoral monobloc intramedullary reamer is used to ream the medullary cavity of femoral bone prior to placing a nail. A range of diameter is proposed in regards with the nail to be implanted and a range of length is proposed in regards with the height of the bone. Different distal coupling are available to connect with existing power tool.
0
-
IM reamer head dove tail Ø16 x 30 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø15.5 x 29 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø15 x 29 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø14.5 x 28 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø14 x 28 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø13.5 x 27 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø13 x 27 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø12.5 x 26 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø12 x 25 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø11.5 x 25 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø11 x 24 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø10.5 x 23 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø10 x 23 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø9.5 x 22 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.
0
-
IM reamer head dove tail Ø9 x 21 mm, can. Ø3.1 mm
MPS Micro Precision Systems AG
Intramedullary reamer head is used in combination with the Intramedullary reamer shaft to ream the medullary cavity of long bones in traumatologic or limb lengthening surgery of the femur, tibia and humerus bones where medullary cavities need to be prepared prior to placing a nail.The intramedullary reamers are intended for use with a guide wire to permit to secure the assembly and a surgical drilling machine. A range of diameter is proposed in regards with the nail to be implanted. Different coupling are available to connect the shaft with existing power tool. The device is reusable.