Nordicneurolab AS
Main Filters
24 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
nordicAktiva
Nordicneurolab AS
NordicNeuroLab’s nordicAktiva is a stimulus presentation and workflow software which controls the presentation of stimuli during fMRI exams and has been designed specifically with the clinical user in mind. With an intuitive interface and detailed, easy-to-follow instructions, the user is guided step-by-step through the process of presenting stimuli during MR image acquisition. nordicAktiva runs on the stimulus presentation PC to which the NNL fMRI Hardware System is connected. Through the latter audiovisual stimuli are presented to, and feedback is collected from the patient.
0
-
nordicBrainEx
Nordicneurolab AS
The nordicBrainEx Software is a post-processing application for dynamic MRI data developed with focuson ease of use and high performance on a standard Windows workstation. The software providescomprehensive functionality for dynamic image analysis and visualization of MRI data, where signalchanges over time are analyzed to determine various modality dependent functional parameters. Thefollowing algorithms provide the main functional analyses of the application.- BOLD: BOLD fMRI analysis is used to highlight small magnetic susceptibility changes in thehuman brain in areas with altered blood-flow resulting from neuronal activity.- DTI: Diffusion analysis is used to visualize local water diffusion properties from the analysis ofdiffusion-weighted MRI data. Fiber tracking utilizes the directional dependency of the diffusionto display the white matter structure in the brain.- DSC: Calculations of perfusion related parameters that provide information about the bloodvessel structure and characteristics. Examples of such maps are blood volume, blood flow, timeto peak, mean transit time and leakage.In addition to these specific functional analyses, the application also provides general visualization tools,a database for data handling, and a reporting feature. This is to ensure that the workflow of theapplication is optimized to ensure efficiency and high throughput in a clinical environment.
0
-
Shielded Interface Unit
Nordicneurolab AS
Shielded Interface Unit (SIU) is part of NordicNeuroLab’s fMRI System.SIU is a shielded enclosure for the Power Supply Unit, Electrostatic Energizer (audio amplifier), Optical Electrical Adapter Unit and Display Interface. SIU is used togheter with NordicNeuroLab’s Visual System and Audio System.SIU hardware configuration is dependent on the system setup and which Visual System components and Audio System components that are included in the fMRI system
0
-
Fiberlink transmitter
Nordicneurolab AS
Fiberlink transmitter is part of NordicNeuroLab’s fMRI System.Fiberlink transmitter converts audio and video signals into an optical signal for transmission.Fiberlink transmitter is used togheter with NordicNeuroLab’s Visual System and Audio System.
0
-
SyncBox
Nordicneurolab AS
SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings.
0
-
ResponseGrip Interface
Nordicneurolab AS
ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces.
0
-
SyncBox
Nordicneurolab AS
SynkBox is part of NordicNeuroLab’s fMRI System.The SyncBox is connected directly to the MRI scanner where it receives timing pulses sent out with each image series and demodulates this signal before it’s forwarded to the stimulus PC. In this way one can ensure that the stimulus presentation software is synchronized with the MRI image recordings.
0
-
ResponseGrip Interface
Nordicneurolab AS
ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PCThe ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces.
0
-
ResponseGrips
Nordicneurolab AS
The ResponseGrip is an MRI-safe patient response device, providing real-time feedback of a patient response. The ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces.
0
-
CommunicationConsole
Nordicneurolab AS
CommunicationConsole is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. The Communication Console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.
0
-
HeadPhones Slim
Nordicneurolab AS
Head Phones Slim is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone Slim is designed specifically for use in the MR environment, and are compatible with MR system up to 3T.
0
-
Headphones
Nordicneurolab AS
Head Phones is part of NordicNeuroLab’s Audio System.The AudioSystem allows auditory signals from the stimulus presentation PC to enter the scanner room and to be presented to the patient wearing a set of headphones. A communication console allows the operator to adjust the sounds from the PC and to speak directly to the patient through a built-in microphone.The Head Phone is designed specifically for use in the MR environment, and are compatible with MR system up to 3T.
0
-
Visual System HD
Nordicneurolab AS
The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)
0
-
Visual System Power Supply
Nordicneurolab AS
Visual System Power Supply (VPS) for NordicNeuroLab's Visual System HDShielded enclosure containing the Power Supply Unit for the Visual System HD which is located in the MR environment. VPS is part of NordicNeuroLab’s VisualSystem HD. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays.
0
-
Visual System HD
Nordicneurolab AS
The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)
0
-
VisualSystem Power Cable (VPC)
Nordicneurolab AS
The VisualSystem HD allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays (Visual System HD)The VisualSystem Power Cable (VPC) provides connection between the VisualSystem Power Supply (VPS) And the coil mounted displays (VHD)
0
-
Control Room Interface
Nordicneurolab AS
Control Room Interface (CRI) is part of Visual System HD.CRI is the interface unit for video signal in (HDMI) and eye tracking video out (HDMI).The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays, Visual System HD.
0
-
Coil Mounted Display
Nordicneurolab AS
Coil Mounted Display is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.Coil Mounted Display is a flexible solution for presenting visual stimuli inside the MR scanner, which is based on OLED technology.
0
-
Inroom Viewing Device
Nordicneurolab AS
NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard HDMI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with an integrated VGA camera.
0
-
LCD Power Supply
Nordicneurolab AS
LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.
0
-
LCD Power Supply
Nordicneurolab AS
LCD Power Supply (LPS) for NordicNeuroLab’s 40inch LCD MonitorShielded enclosure containing the Power Supply Unit for the LCD Monitor which is located in the MR environment. LPS is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.
0
-
Inroom Viewing Device
Nordicneurolab AS
NordicNeuroLab’s LCD monitor (NNL MRI InroomViewingDevice LCD 40) is a complete, state-of-the-art solution designed specifically for use in the MR environment.LCD 40 is part of NordicNeuroLab’s VisualSystem. The VisualSystem allows video signals from the stimulus presentation PC to enter the shielded scanner room and to be presented to the patient through a set of coil-mounted displays or by an in-room LCD monitor.LCD 40 is a 40 inch LCD (Liquid Crystal Display) monitor, compatible with MR system up to 3T.The LCD monitor uses standard DVI display signal, and can be connected to any computer or video output device with digital outputs.The LCD monitor are capable to show video signals in 4K UHD format (3840x2160 pixels)The LCD monitor is equipped with a integrated VGA camera.