RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Main Filters
11 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
FerriSmart
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
FerriSmart is a stand-alone software application that automatically analyses multi slice, spin echo MRI data sets encompassing the abdomen to determine the signal decay rate (R2) that is used to characterize iron loading in the liver, which is then transformed by a defined calibration curve to provide a quantitative measure of liver iron concentrations in vivo.The software application is a measuring medical device intended to be hosted either in a cloud-based or on site hosted platform and used directly by the radiographer. It does not drive the MRI machine and does not come into direct contact with patients.The result report provides the patient’s average LIC reported in micromole and milligram per gram dry weight of liver. The images analysed are included in the report for review by the radiologist. The results are intended to assist in clinical diagnosis, and/or in making decisions concerning clinical management.FerriSmart is indicated to: • measure liver iron concentration in individuals with confirmed or suspected systemic iron overload • monitor liver iron burden in transfusion dependent thalassemia patients and patients with sickle cell disease receiving blood transfusions • aid in the identification and monitoring of non-transfusion-dependent thalassemia patients receiving therapy with deferasirox.
0
-
HepaFatSmart
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Standalone software as medical device (SaMD) designed to automatically analyse within seconds magnetic resonance imaging (MRI) datasets to generate an estimate of the patient’s volumetric liver fat fraction (VLFF), converted into proton density fat fraction (PDFF) and steatosis grade. No user input is required for the analysis thus minimising the impact of human error on obtained results. HepaFatSmart is intended for the quantitative evaluation of volumetric liver fat fraction (VLFF), proton density fat fraction (PDFF) and liver steatosis grading.It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver.When interpreted by a trained physician, the results provide information that can aid in diagnosis.HepaFatSmart is indicated to:• Support clinical diagnoses in individuals with confirmed or suspected fatty liver disease; • Assessment of liver fat content to support the subsequent clinical decision-making processes for patients under management of diseases such as non-alcoholic fatty liver disease (NAFLD), non-alcoholic steatohepatitis (NASH), viral hepatitis. • Support the subsequent clinical decision-making processes for patients Results, when interpreted by a trained physician can be used to support clinical diagnoses about the status of liver fat content, the subsequent clinical decision-making processes for the management of fatty liver related diseases.
0
-
R2*/T2* Phantom
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
The R2*/T2* phantom is a medical device accessory intended to be used as an alternative to human test subject to avoid potential complications for an MRI centre in order to evaluate that the scanning protocol have been correctly set up for the analysis of cardiac R2* and T2* values using the CardiacT2* on 1.5T and 3T MRI scanners. The R2*/T2* Phantom consists of an amber bottle having 09 (nine) plastic tubes (30mL) of 0.8% Agarose (C24H38O19) gel doped with varying known concentrations (0.10 mM to 3.2 mM) of manganese chloride (MnCl2).
0
-
T2CMR Phantom
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Cardiovascular magnetic resonance (CMR) T2 mapping is key to quantifying myocardial inflammation. The T2CMR Phantom is made of nine (9) plastic tubes (30mL) containing different concentrations of nickel chloride (NiCl2) in agarose. T2CMR Phantom is provided to MRI Centres for the verification of T2-mapping stability across different 1.5T and 3T scanners (different manufacturers and models) and to understand the feasibility of delivering a “T2 standard”.
0
-
T1CMR Phantom (3.0T)
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
The T1CMR Phantom contains a range of nickel chloride in agarose solutions that mimic cardiac T1 and T2 values. T1 measurement is used to calculate the extravascular volume fraction (ECV) to detect diffuse myocardial fibrosis. It is provided to MRI Centres for the verification of T1-mapping stability across different 3.0T scanners (different manufacturers and models) and to understand the feasibility of delivering a “T1 standard”.
0
-
FerriSmart
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
FerriSmart is a standalone software as a medical device indicated for the evaluation of liver R2 and liver iron concentration (LIC) from MRI images for the full spectrum of R2 and LIC known clinically. It automatically analyses multi slice, spin echo MRI data sets encompassing the abdomen to determine the signal decay rate (R2) that is used to characterize iron loading in the liver, which is then transformed by a defined calibration curve to provide a quantitative measure of liver iron concentrations in vivo.The software application is intended to be hosted either in a cloud-based or on site hosted platform and used directly by the radiographer. It does not drive the MRI machine and does not come into direct contact with patients.The result report provides the patient’s average LIC reported in micromole and milligram per gram dry weight of liver. The images analysed are included in the report for review by the radiologist. The results are intended to assist in clinical diagnosis, and/or in making decisions concerning clinical management.FerriSmart is indicated to: • Support clinical diagnoses in individuals with confirmed or suspected liver iron overload; • Assessment of liver iron loading to support the subsequent clinical decision-making for patients under management of diseases such as thalassaemia disorders or hereditary haemochromatosis. • Results, when interpreted by a trained physician can be used to support clinical diagnoses about the status of liver iron concentration, the subsequent clinical decision-making processes for the management of iron overload diseases.
0
-
HepaFat-Scan
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Standalone software application to facilitate the import and visualization of multi slice, gradient echo MRI data sets encompassing the abdomen, with functionality independent of the MRI equipment, to provide objective and reproducible determination of the triglyceride fat fraction in magnetic resonance images of the liver. It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver.HepaFat-Scan is a software device intended for quantitative measurement of the triglyceride fat fraction in magnetic resonance images of the liver. It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver.When interpreted by a trained physician, the results provide information that can aid in diagnosis.
0
-
T1CMR Phantom (1.5T)
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
The T1CMR Phantom contains a range of nickel chloride in agarose solutions that mimic cardiac T1 and T2 values. T1 measurement is used to calculate the extravascular volume fraction (ECV) to detect diffuse myocardial fibrosis. It is provided to MRI Centres for the verification of T1-mapping stability across different 1.5T scanners (different manufacturers and models) and to understand the feasibility of delivering a “T1 standard”.
0
-
FerriScan Phantom
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Sealed pack containing 15 vials of varying concentrations (0 mM to 3.2 mM) of aqueous manganese chloride solutions in 10 mM hydrochloride acid solution. It is intended to be used for verification / re-verification of correct MRI scanner sequence configuration for the use of R2-MRI Analysis System (FerriScan)
0
-
HepaFat-AI
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Standalone software platform designed to automatically analyse within seconds magnetic resonance imaging (MRI) datasets to generate an estimate of the patient’s volumetric liver fat fraction (VLFF), converted into proton density fat fraction (PDFF) and steatosis grade. No user input is required for the analysis thus minimising the impact of human error on obtained results. HepaFat-AI is intended for quantitative measurement of the triglyceride fat fraction in magnetic resonance images of the liver, also known as volumetric liver fat fraction (VLFF). It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver.When interpreted by a trained physician, the results provide information that can aid in diagnosis.HepaFat-AI is indicated to:• Assess the volumetric liver fat fraction, proton density fat fraction and steatosis grade in individuals with confirmed or suspected fatty liver disease;• Monitor liver fat content in patients undergoing weight loss management;• Aid in the assessment and screening of living donors for liver transplant.
0
-
FerriScan, Cardiac T2*
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Software tool to facilitate the import and visualization of multi slice, spin echo MRI data sets encompassing the liver and cardiac tissue, with functionality independent of the MRI equipment vendor. The operational principle is based on fitting signal decay curves to the image signal intensities at the different echo times for the MR data set on a voxel by voxel (3 D pixel) basis to determine transverse relaxation rate (R2) images, that may be further transformed by a defined calibration to provide a quantitative measure of liver iron concentrations in vivo and fitting signal decay curves to magnetic resonance image signal intensities acquired at different echo times on a voxel by voxel (3 D pixel) basis to determine the signal decay rate (R2*) and time (T2*)The obtained results can be used for the following purposes:1. Supporting clinical diagnoses about the status of liver iron concentration and cardiac iron.2. Supporting the subsequent clinical decision making processes.3. Supporting the use in clinical research trials, directed at studying changes in liver iron concentration as a result of interventions.4. It contains an image viewer for importing DICOM images, browsing through patient datasets, viewing images and performing region of interest analysis.