RevMed
Home/Specialty/Neurology/Instrument, Shunt System Implantation/Single Pass Tunneling Guidewire - Medium

ARKIS BIOSCIENCES INC. 41.157.102 Single Pass Tunneling Guidewire - Medium

Company Name
ARKIS BIOSCIENCES INC.
Catalog Number
41.157.102

Description

The Single Pass Tunneling Guidewire kit is designed to facilitate the subcutaneous passage of shunt tubing from a frontal scalp incision, or an incision on the neck, to an incision site on the torso when implanting a ventricular shunting system in patients greater than five (5) years old with a normal skull and normal skin.
Have questions or need more information? Contact Us

Pricing
Summary

Price Not Available
Out of Stock
Interested in this product?
Contact us or login to add to your watchlist.

Related Items

-

MOMENTIS SURGICAL LTD - Anovo Surgeon Console and Anovo Power cable

The AnovoTM Surgical System is a robotic-assisted device intended for use by laparoscopic trained physicians for endoscopic manipulation of tissue, using graspers and electrosurgery devices during single-site laparoscopic gynecologic procedures such as benign hysterectomy and salpingo-oophorectomy through a transvaginal access point. The system composed of Anovo Surgeon Console, two sterile instruments (Anovo Instrument ARMS), bed-mounted Robotic Control Unit (RCU) and Anovo System Accessories (Unit cables, Sterile Drapes, Robotic Control Unit Support System (RCUSS) and Vaginal Access Kit). Anovo Surgeon Console (UDI # 07290018151013) packed with its power cable (UDI # 07290018151037)The Anovo Surgeon Console comprised of Arm Controllers (Joysticks and Thumbsticks), an Adjustable Controllers Stand, a PC with Touch Screen, Manual Release Tool and the Power Adapter, and allowing the operating surgeon to operate the Anovo Instrument Arms. There are two sets of Arm Controllers for the Anovo System: two Thumbsticks and two ARMS Controllers. The ARMS Controllers are enabled only when the system is at “resume” state and allow for the accurate control of the Anovo Instrument ARMS during the surgical procedure. Like the Anovo Instrument Arm, each ARMS Controllers has three joints: wrist, elbow and shoulder, so that each Anovo Instrument ARM moves accordingly to Controller's movement. The surgeon-held Controller handle is above the elbow joint and allows for multiple functionality transitions.
Out of Stock
General & Plastic Surgery
-

RESONANCE HEALTH ANALYSIS SERVICES PTY LTD - HepaFatSmart

Standalone software as medical device (SaMD) designed to automatically analyse within seconds magnetic resonance imaging (MRI) datasets to generate an estimate of the patient’s volumetric liver fat fraction (VLFF), converted into proton density fat fraction (PDFF) and steatosis grade. No user input is required for the analysis thus minimising the impact of human error on obtained results. HepaFatSmart is intended for the quantitative evaluation of volumetric liver fat fraction (VLFF), proton density fat fraction (PDFF) and liver steatosis grading.It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver.When interpreted by a trained physician, the results provide information that can aid in diagnosis.HepaFatSmart is indicated to:• Support clinical diagnoses in individuals with confirmed or suspected fatty liver disease; • Assessment of liver fat content to support the subsequent clinical decision-making processes for patients under management of diseases such as non-alcoholic fatty liver disease (NAFLD), non-alcoholic steatohepatitis (NASH), viral hepatitis. • Support the subsequent clinical decision-making processes for patients Results, when interpreted by a trained physician can be used to support clinical diagnoses about the status of liver fat content, the subsequent clinical decision-making processes for the management of fatty liver related diseases.
Out of Stock
Radiology

Additional Details

Device Identifier
00866614000139
Is RX
Yes
Is Over the Counter
No
Requires Sterilization
No
Is Sterile
Yes
Is Single Use
Yes

Barcode Mapping

Unit of MeasurementEachesGTIN
Each100866614000139