RevMed
Home/Specialty/Hematology/Test, Time, Partial Thromboplastin/REAADS Anti-Cardiolipin IgG/IgM Semi-Quantitative Test Kit (96 Well)

CORGENIX MEDICAL CORPORATION 023-001 REAADS Anti-Cardiolipin IgG/IgM Semi-Quantitative Test Kit (96 Well)

Company Name
CORGENIX MEDICAL CORPORATION
Catalog Number
023-001
UOMs
  • Each

Description

INTENDED USE For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use.SUMMARY AND EXPLANATION OF THE TEST Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After the removal of unbound serum proteins by washing, antibodies specific for human IgG or IgM labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of aCL antibodies. Results are obtained by reading the O.D. of each test well with a spectrophotometer. Calibrator sera are provided, with the IgG and IgM aCL concentrations expressed in GPL or MPL units, respectively. The O.D. values of all the other samples are multiplied by the conversion factors to obtain IgG and IgM aCL antibody concentrations in standard units. Control and patient results are determined from the calibration curve. Refer to Product Product Insert.
Have questions, or need more information? Contact Us

Pricing
Summary

Price Not Available
Out of Stock
Interested in this product?
Contact us or login to add to your watchlist.

Related Items

Additional Details

Device Identifier
00855360006045
Is RX
Yes
Is Over the Counter
No
Requires Sterilization
No
Is Sterile
No
Is Single Use
Yes

Barcode Mapping

Unit of MeasurementEachesGTIN
Each100855360006045