RevMed

Other

83,942 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
SOMNOscreen plus Cardio RESP Screener Set
SOMNOmedics GmbH
0
-
SOMNOscreen plus RC easy Set
SOMNOmedics GmbH
0
-
Vaporflex®
Joimax GmbH
Vaporflex® KIT2 short for joimax® Endovapor® 2
0
-
Vaporflex®
Joimax GmbH
Vaporflex® KIT1 short for joimax® Endovapor®
0
-
Vaporflex®
Joimax GmbH
Vaporflex® Handle and Shaft
0
-
TPE Plasma Exchange Set
Fresenius Kabi AG
Therapeutic plasma exchange, disposable variant of 9400401 (Therapeutic plasma exchange, red blood cell exchange).
0
-
COM.TEC
Fresenius Kabi AG
The COM.TEC Blood Cell Separator is a blood cell separator which utilizes centrifugal force as the basis for operation. The fields of application are as follows:- Plasma exchange- Plasma treatment
0
-
AMICUS Exchange Kit - Therapeutics
Fresenius Kabi AG
For Therapeutic Plasma Exchange (TPE) Procedure. For Red Blood Cell Exchange (RBCX) Procedures. For Use with the AMICUS Separator. Sterile Fluid Path.
0
-
AMICUS Separator Software
Fresenius Kabi AG
Software version for Amicus Separator
0
-
Bone Marrow Collection Kit with Flexible Pre-Filter and Inline Filters
Fresenius Kabi AG
For Collection and Filtration of up to 1.2 Liters of Aspirated Bone Marrow. Must be used with the Bone Marrow Collection Stand.
0
-
Bone Marrow Collection Kit with Flexible Pre-Filter and Inline Filters
Fresenius Kabi AG
For Collection and Filtration of up to 1.2 Liters of Aspirated Bone Marrow. Must be used with the Bone Marrow Collection Stand.
0
-
Blood Component Filter Set with Vented Spike and Luer Adapter
Fresenius Kabi AG
For use with the AMICUS separator. Sterile Fluid Path.
0
-
AMICUS Exchange Kit
Fresenius Kabi AG
For Therapeutic Plasma Exchange (TPE) Procedure. For Use with the AMICUS Separator. Sterile Fluid Path.
0
-
Tomosynthesis option
Siemens Healthcare GmbH
Option to the MAMMOMAT Inspiration FFDM system to acquire tomosynthesis images for mammography
0
-
easypod
EMD Serono, Inc.
easypod is an electromechanical auto-injector which automatically administers a pre-set dose of Saizen (somatropin [rDNA origin]) in cartridges.
0
-
one.click
EMD Serono, Inc.
one.click is a mechanical auto-injector which automatically administers a pre-set dose of Saizen (somatropin [rNDA origin]) in cartridges.
0
-
3M™
3M Deutschland GmbH
3M™ Astringent Retraction Paste Sample (3), 56943
0
-
3M™
3M Deutschland GmbH
3M™ Astringent Retraction Paste, Refill Pack, 56944
0
-
3M™
3M Deutschland GmbH
3M™ Astringent Retraction Paste, Value Pack, 56945
0
-
Impregum™ Penta™ Super Quick
3M Deutschland GmbH
3M™ Impregum™ Penta™ Super Quick MB Introductory Kit Dual, 69414
0
-
Impregum™ Penta™ Super Quick
3M Deutschland GmbH
3M™ Impregum™ Penta™ Super Quick HB/LB Introductory Kit Dual, 69407
0
-
Impregum™ Penta™ Super Quick
3M Deutschland GmbH
3M™ Impregum™ Penta™ Super Quick MB/LB Introductory Kit Dual, 69415
0
-
therascreen® BRAF RGQ PCR Kit
QIAGEN GmbH
The therascreen BRAF V600E RGQ PCR Kit is a real-time PCR test for the qualitative detection of V600E mutations in the BRAF gene using genomic DNA extracted from formalin-fixed paraffin-embedded (FFPE) human colorectal cancer (CRC) tumor tissue. The therascreen BRAF V600E RGQ PCR Kit is an in vitro diagnostic device intended to be used as an aid in selecting patients with metastatic colorectal cancer (mCRC) whose tumors carry the BRAF V600E mutation for treatment with BRAFTOVI (encorafenib) in combination with cetuximab. The therascreen BRAF V600E RGQ PCR Kit is for use on the Rotor-Gene Q MDx (US)instrument. The therascreen BRAF V600E RGQ PCR Kit is intended for in vitro diagnostic use.
0
-
therascreen® PIK3CA RGQ PCR Kit
QIAGEN GmbH
The therascreen PIK3CA RGQ PCR Kit is a real-time qualitative PCR test for the detection of 11 mutations in the phosphatidylinositol 3-kinase catalytic subunit alpha (PIK3CA) gene (Exon 7: C420R; Exon 9: E542K, E545A, E545D [1635G>T only], E545G, E545K, Q546E, Q546R; and Exon 20: H1047L, H1047R, H1047Y) using genomic DNA (gDNA) extracted from formalin-fixed, paraffin-embedded (FFPE) breast tumor tissue or circulating tumor DNA (ctDNA) from plasma derived from K2EDTA anticoagulated peripheral whole blood taken from patients with breast cancer. The test is intended to aid clinicians in identifying breast cancer patients who may be eligible for treatment with PIQRAY® (alpelisib) based on a PIK3CA Mutation Detected result. Patients whose FFPE tissue or plasma specimen produces a positive therascreen PIK3CA RGQ PCR Kit test result for the presence of one or more PIK3CA mutations are eligible for treatment with PIQRAY (alpelisib). Patients whose plasma specimen produces a negative result using this test should be reflexed to testing with FFPE tumor tissue for the presence of PIK3CA mutations. FFPE tumor specimens are processed using the QIAamp DSP DNA FFPE Tissue Kit for manual sample preparation. K2EDTA anticoagulated whole peripheral venous blood plasma specimens are processed using the QIAamp DSP Circulating Nucleic Acid Kit for manual sample preparation. For both specimen types, the Rotor-Gene Q (RGQ) MDx (US) instrument is used for automated amplification and detection. The Kit is to be used by trained personnel in a professional laboratory environment.
0
-
therascreen® FGFR RGQ RT-PCR Kit
QIAGEN GmbH
The therascreen FGFR RGQ RT-PCR Kit is a real-time, reverse transcription PCR test for the qualitative detection of two point mutations in exon 7 [p.R248C (c.742C>T), p.S249C (c.746C>G)], two point mutations in exon 10 [p.G370C (c.1108G>T) and p.Y373C (c.1118A>G)] and two fusions (FGFR3:TACC3v1 and FGFR3:TACC3v3) in the fibroblast growth factor receptor 3 (FGFR3) gene in RNA samples derived from formalin-fixed paraffin-embedded (FFPE) urothelial tumor tissue. The test is indicated for use as an aid in identifying patients with cases of urothelial cancer (UC) which harbor these alterations and are therefore eligible for treatment with BALVERSA™ (erdafitinib).Specimens are processed using the RNeasy DSP FFPE Kit for manual sample preparation followed by reverse transcription and then automated amplification and detection on the Rotor-Gene Q MDx (US) instrument.
0
-
artus® CMV QS-RGQ MDx Kit
QIAGEN GmbH
0
-
QuantiFERON®-TB Gold Plus
QIAGEN SCIENCES INC.
QFT-Plus Reference Lab Pack Elisa Kit
0
-
QuantiFERON®-TB Gold Plus
QIAGEN SCIENCES INC.
QFT-Plus 2 Plate Elisa Kit
0
-
DML 3000
QIAGEN SCIENCES INC.
0
-
QuantiFERON-TB Gold Reference Lab Pack
QIAGEN SCIENCES INC.
0
-
QuantiFERON-TB Gold 2 Plate Kit
QIAGEN SCIENCES INC.
0
-
artus® CMV RGQ MDx Kit
QIAGEN GmbH
0
-
therascreen® EGFR RGQ PCR Kit
QIAGEN GmbH
0
-
therascreen® KRAS RGQ PCR Kit
QIAGEN GmbH
0
-
hc2 High-Risk HPV DNA Test
QIAGEN SCIENCES INC.
digene® HC2 High-Risk HPV DNA Test (1-Plate Kit)
0
-
hc2 HPV DNA Test
QIAGEN SCIENCES INC.
digene® HC2 HPV DNA Test (Low-Risk HPV and High-Risk HPV)
0
-
hc2 High-Risk HPV DNA Test
QIAGEN SCIENCES INC.
digene® HC2 High-Risk HPV DNA Test (4-Plate Kit)
0
-
Waste Transfer Set
Fresenius Kabi AG
For Red Blood Cell Exchange (RBCX) Procedures. For use with the AMICUS Separator. Sterile Fluid Path.
0
-
Blood Component Filter Set with Vented Spike and Luer Adapter
Fresenius Kabi AG
For Administration of Blood and Blood Components During a Therapeutic Plasma Exchange (TPE) or Red Blood Cell Exchange (RBCX) Therapeutic Apheresis Procedure. For use with the AMICUS separator. Sterile Fluid Path.
0
-
P1R Plasma Treatment Set
Fresenius Kabi AG
Therapeutic Plasma Treatment (e.g. LDL-apheresis)
0
-
Proximel NB AG Silicone Dressing 6X6
HARTMANN USA, INC.
Proximel NB AG Silicone Dressing 6X6
0
-
Proximel NB AG Silicone Dressing 8x8
HARTMANN USA, INC.
Proximel NB AG Silicone Dressing 8x8
0
-
Proximel NB AG Silicone Dressing 4x4
HARTMANN USA, INC.
Proximel NB AG Silicone Dressing 4x4
0
-
STERILUX AMD ST BULKY GZ 4.5x4.1YD 6P
HARTMANN USA, INC.
STERILUX AMD ST BULKY GZ 4.5x4.1YD 6P
0
-
Dornier MedTech
Dornier MedTech GmbH
UIMS Viewing Station SC High Line
0
-
Dornier MedTech
Dornier MedTech GmbH
UIMS Viewing Station SC Low Line
0
-
Dornier MedTech
Dornier MedTech GmbH
UIMS Viewing Station
0
-
CliniMACS Tubing Set LS
Miltenyi Biotec B.V. & Co. KG
CliniMACS® Tubing Set (LS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
0
-
CliniMACS Tubing Set TS
Miltenyi Biotec B.V. & Co. KG
CliniMACS® Tubing Set (TS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
0
-
CliniMACS CD34 Reagent
Miltenyi Biotec B.V. & Co. KG
CliniMACS® CD34 Reagent is a dark amber, non-viscous, colloidal solution containing an antibody conjugate in buffer. The conjugate consists of a murine IgG1 monoclonal antibody directed against the Class II epitope of the human CD34 antigen, which is chemically conjugated to dextran beads having an iron oxide/hydroxide core used in conjuction with the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
  1. 1
  2. …
  3. 599
  4. 600
  5. 601
  6. …
  7. 1,679
PreviousNext