RevMed
Home/Specialty/Cardiovascular/Percutaneous Catheter For Creation Of An Arteriovenous Fistula For Hemodialysis Access

Percutaneous Catheter For Creation Of An Arteriovenous Fistula For Hemodialysis Access

11 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
Ellipsys Vascular Access System
AVENU MEDICAL, INC.
The Ellipsys Vascular Access System is indicated for the creation of a proximal radial artery to perforating vein anastomosis via a retrograde venous access approach in patients with a minimum vessel diameter of 2.0mm and less than 1.5mm of separation between the artery and vein at the fistula creation site who have chronic kidney disease requiring dialysis.The main components of the Ellipsys Vascular Access System are the Ellipsys Catheter, the Ellipsys Crossing Needle, and the Ellipsys Power Controller. The Crossing Needle and Catheter are single-use, sterile disposables that are packaged together, and referred to as the Ellipsys Vascular Access Kit. The Ellipsys Power Controller is a reusable, non-sterile portable electronic console that is packaged and provided separately.
0
-
Ellipsys Vascular Access System
AVENU MEDICAL, INC.
The Ellipsys® Vascular Access System is indicated for the creation of a proximal radial artery to perforating vein anastomosis via a retrograde venous access approach in patients with a minimum vessel diameter of 2.0mm and less than 1.5mm of separation between the artery and vein at the fistula creation site who have chronic kidney disease requiring dialysis. The main components of the Ellipsys Vascular Access System are the Ellipsys Catheter, the Ellipsys Crossing Needle, and the Ellipsys Power Controller. The Crossing Needle and Catheter are single-use, sterile disposables. The Ellipsys Power Controller is a reusable, non-sterile portable electronic console that is packaged and provided separately.
0
-
Ellipsys Power Controller
AVENU MEDICAL, INC.
The Ellipsys® Power Controller is the reusable control unit for the Ellipsys® Vascular Access System. The Controller is a portable electronic console with AC power input, internal control electronics, a Catheter connection receptacle, and LCD display. The Controller delivers power to the Catheter heating element and guides the user through the procedure with visual prompts. The power controller is only compatible with the Avenu Medical Ellipsys® Catheter.
0
-
Ellipsys Power Controller
AVENU MEDICAL, INC.
0
-
WavelinQ
TVA MEDICAL, INC.
WavelinQ™ 6F endoAVF System
0
-
WavelinQ
CLEARSTREAM TECHNOLOGIES LIMITED
WavelinQ™ EndoAVF System
0
-
WavelinQ
Bard Peripheral Vascular, Inc.
WavelinQ™ 4F EndoAVF System
0
-
Ellipsys Power Controller
AVENU MEDICAL, INC.
The Ellipsys® Power Controller is the reusable control unit for the Ellipsys® Vascular Access System. The Controller is a portable electronic console with AC power input, internal control electronics, a Catheter connection receptacle, and LCD display. The Controller delivers power to the Catheter heating element and guides the user through the procedure with visual prompts. The power controller is only compatible with the Avenu Medical Ellipsys® Catheter.
0
-
Ellipsys Vascular Access System
AVENU MEDICAL, INC.
The Ellipsys® Vascular Access System is indicated for the creation of a proximal radial artery to perforating vein anastomosis via a retrograde venous access approach in patients with a minimum vessel diameter of 2.0mm and less than 1.5mm of separation between the artery and vein at the fistula creation site who have chronic kidney disease requiring dialysis. The main components of the Ellipsys Vascular Access System are the Ellipsys Catheter, the Ellipsys Crossing Needle, and the Ellipsys Power Controller. The Crossing Needle and Catheter are single-use, sterile disposables. The Ellipsys Power Controller is a reusable, non-sterile portable electronic console that is packaged and provided separately.
0
-
Ellipsys Vascular Access System
AVENU MEDICAL, INC.
The Ellipsys® Vascular Access System is indicated for the creation of a proximal radial artery to perforating vein anastomosis via a retrograde venous access approach in patients with a minimum vessel diameter of 2.0mm and less than 1.5mm of separation between the artery and vein at the fistula creation site who have chronic kidney disease requiring dialysis. The main components of the Ellipsys Vascular Access System are the Ellipsys Catheter, the Ellipsys Crossing Needle, and the Ellipsys Power Controller. The Crossing Needle and Catheter are single-use, sterile disposables. The Ellipsys Power Controller is a reusable, non-sterile portable electronic console that is packaged and provided separately.
0
-
Ellipsys Power Controller
AVENU MEDICAL, INC.
The Ellipsys® Power Controller is the reusable control unit for the Ellipsys® Vascular Access System. The Controller is a portable electronic console with AC power input, internal control electronics, a Catheter connection receptacle, and LCD display. The Controller delivers power to the Catheter heating element and guides the user through the procedure with visual prompts. The power controller is only compatible with the Avenu Medical Ellipsys® Catheter.