RevMed
Home/Specialty/Neurology/Shunt, Central Nervous System And Components

Shunt, Central Nervous System And Components

4,027 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
Integra Peritoneal Open-Ended Catheter With Slits
Integra
Integra Peritoneal Open-Ended Catheter With Slits PERITONEAL CATHETER, 90CM LENGTH 12 mm H2O at a flow rate of 23 ml/hr.
0
-
Integra Spetzler™ Lumbar Peritoneal Shunt System
Integra
LONG SPETZLER 105CM LP SHUNT The Spetzler Lumbar Peritoneal Shunt System is designed to shunt cerebrospinal fluid (CSF) from the lumbar subarachnoid space to the peritoneum. Due to the small diameter of the catheter tubing, shunting may be accomplished by percutaneous techniques. A variety of devices are available: a one-piece model without a reservoir; separate large or small reservoirs that contain a one-way valve, which may be used when a flushing capability is required; and a separate miter valve, available in low, medium, or high pressure, which may be used when added resistance is desired.
0
-
Integra®
Integra
3 FRENCH T-TUBEThe Integra Edwards-Barbaro Syringo-Peritoneal Shunt is designed to provide continuous drainage of fluid from within a spinal cord cyst to a site outside the spinal canal. The T-tube diameter is small to minimize the size of the myelotomy and the catheter is flexible to minimize the spinal cord manipulation necessary to insert the tube into a spinal cord cyst. The T-shape allows drainage above and below the myelotomy site, helps prevent kinking by providing a right-angle exit through the dura, and reduces the risk of migration out of the spinal cord. The multi-holed catheter reduces the risk of clogging at the spinal end of the system. The suture tab allows the T-tube to be anchored to the dura or paraspinous muscles without the risk of shunt occlusion associated with a circumferential ligature. If a step down connector is used, it adapts the T-tube diameter to the peritoneal reflux control catheter.
0
-
Integra®
Integra
INTEGRA® STERILE LUER CONNECTOR
0
-
Integra LPV II Valve Shunt Kit
Integra
MINI LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, mini, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability.
0
-
Integra LPV II Valve Shunt Kit
Integra
STANDARD LPV II SHUNT KIT, MED.The Integra LPV II Valve Shunt Kits are designed to deliver CSF from the ventricles of the brain to the peritoneal cavity. The kit contains a LPV II valve, standard, a Pudenz Ventricular Catheter and an integral, open-ended kink resistant catheter attached to the outlet of the valve. The kit is available in a medium pressure range. All valves and catheters contain barium sulfate for x-ray detectability.
0
-
Integra LPV II Valve
Integra
MINI LPV II VALVE, HIGHThe Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal high pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure.
0
-
Integra LPV II Valve
Integra
MINI LPV II VALVE, MED.The Integra LVP II Valve, Mini is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal medium pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure.
0
-
Integra LPV II Valve
Integra
STANDARD LPV II VALVE, LOWThe Integra LVP II Valve, Standard is a silicone elastomer valve used for the treatment of hydrocephalic patients when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. The valve incorporates an internal low pressure valve assembly which is mounted distal to an integral pumping reservoir for proximal control of CSF flow. The device also provides one-way flow control. Integral occluders are incorporated on the proximal and distal end of the valve to allow manual control of flushing or pumping of CSF proximally or distally. The device is fitted with a polypropylene needle guard, designed to prevent inadvertent needle puncture through the base of the reservoir during percutaneous injection. The valve contains an integral plastic connector on each end to simplify the assembly procedure.
0
-
Integra®
Integra
Integra Large Bore Tubing Set
0
-
Integra®
Integra
Integra® Lumbar Drainage Accessory Kit with Guide Wire
0
-
TraumaCath™
Integra
TraumaCath™ Large Style Ventricular Catheter Set
0
-
Hermetic™ II
Integra
Hermetic™ II Hermetic™ Lumbar Drainage Accessory Kit
0
-
Hermetic™
Integra
Hermetic™ VENTRICULAR CATHETER SET
0
-
Integra®
Integra
Integra® Pudenz Ventricular Catheter Pudenz Ventricular Catheter with Stylet
0
-
Integra®
Integra
Integra® Pudenz Ventricular Catheter with Stylet
0
-
Integra®
Integra
Integra® Pudenz Peritoneal Catheter Pudenz Peritoneal Catheter
0
-
Integra®
Integra
Integra® Pudenz Peritoneal Catheter Pudenz Peritoneal Catheter
0
-
Integra®
Integra
Integra® Pudenz Peritoneal Catheter Pudenz Peritoneal Catheter
0
-
NeuroView™
Integra
NEUROVIEW™ Endoscopic Ventricular Catheter
0
-
Integra®
Integra
Integra® Pudenz Infant Cardiac Catheter Barium Impregnated Barium Stripe
0
-
Integra®
Integra
Integra® Pudenz Infant Cardiac Catheter Barium Impregnated Barium Stripe
0
-
Integra®
Integra
Integra® Pudenz Cardiac Catheter Barium Impregnated Stripe Radiopaque Tantalum Graduations
0
-
Integra®
Integra
Integra® Pudenz Cardiac Catheter Barium Impregnated Stripe Radiopaque Tantalum Graduations
0
-
Integra Mishler Dual Chamber Flushing Valve
Integra
VALVE FLUSH F/B D/C W/CONNECTORThe Integra Mishler Dual Chamber Flushing valve, Flat Bottom Design incorporates two separate interior chambers to provide two-way flow control when shunting cerebrospinal fluid (CSF) from the ventricles of the brain. This silicone elastomer flushing valve is available with or without an integral Anti-Siphon Device. The flat bottom configuration eliminates the need for a formal burr hole, provides greater latitude in positioning the flushing valve and allows the ventricular catheter to be revised without disturbing the flushing valve. Due to the dual chamber feature, the proximal and distal catheters may be flushed separately or simultaneously. The flow of CSF from the ventricular catheter is controlled by a miter valve located on the vertical chamber divider. This valve is designed to open under a medium positive ventricular pressure and close under a negative pressure. The flushing valve dome is marked with an arrow to indicate the CSF flow direction. The flange overlying the skull contains sutural holes to facilitate securing the device to the periosteum.
0
-
Mini Integra®
Integra
Mini Integra® CSF Reservoir, Dual Side-Inlet
0
-
Mini Integra®
Integra
Mini Integra® CSF Reservoir, Convertible
0
-
Mini Integra®
Integra
Mini Integra® CSF Reservoir, Side-Inlet
0
-
Mini Integra®
Integra
Mini Integra® CSF Reservoir, Standard
0
-
Integra CSF ventricular catheter guide
Integra
Integra CSF Ventricular Catheter Guide
0
-
Integra Spetzler™ Lumbar Peritoneal Shunt System
Integra
TUOHY NEEDLE 14g 6" for Lumbar Peritoneal Shunt A 6-inch
0
-
AccuDrain®
Integra
AccuDrain® Laser Level
0
-
Hermetic™
Integra
Hermetic™ External CSF Drainage System with Pressure Tubing
0
-
MoniTorr ICP™ Drainage Bag
Integra
Sterile latex free MoniTorr ICP Drainage Bag
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalus hunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features of the system include a closed sterile fluid path, calibrated 75mL graduated burette, 700mL drainage bag, anti-microbial hydrophobic vent, two needless sampling sites, a patient stopcock, a four-way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level of laser device can be attached. The transparent graduated burette provides visualization of the flow and clarify of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain®
Integra
AccuDrain® External CSF Drainage System with Anti-Reflux Valve
0
-
AccuDrain®
Integra
AccuDrain® External CSF Drainage System with Anti-Reflux Valve
0
-
AccuDrain® External CSF Drainage System
Integra
ACCUDRAIN SPECIAL SYSTEMThe AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and Intracranial Pressure (ICP) monitoring. Monitoring of Intracranial Pressure (ICP) is usually performed in selected patients with severe head injury, ubarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring Common features to the System include a closed sterile fluid path, calibrated 75ml graduated burette, 700ml drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four-way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
ACCUDRAIN SPECIAL SYSTEMThe AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid spaceto a drainage bag. System components facilitate CSF drainage, CSF sampling and Intracranial Pressure (ICP) monitoring. Monitoring of Intracranial Pressure (ICP) is usually performed in selected patients with severe head injury, ubarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring Common features to the System include a closed sterile fluid path, calibrated 75ml graduated burette, 700ml drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four-way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualizationof the flow and clarity of the CSF, and allows for volumetric readings to bemade prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
AccuDrain® External CSF Drainage System
Integra
The AccuDrain™ External CSF Drainage System is used to drain cerebrospinal fluid (CSF) from the ventricles of the brain or the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, CSF sampling and intracranial pressure (ICP) monitoring. Monitoring of intracranial pressure (ICP) is usually performed in selected patients with severe head injury, subarachnoid hemorrhage, Reyes syndrome or similar encephalopathies, hydrocephalus, hydrocephalic shunt infections, intracranial hemorrhage and pre and/or post operative monitoring. Common features to the System include a closed sterile fluid path, calibrated 75mL graduated burette stopcock, 700mL drainage bag, anti-microbial hydrophobic vent, two needleless sampling sites, a patient stopcock, a four way high flow burette stopcock, cord suspension, red burette height indicator, and integral attachment feature. A line level or laser device can be attached. The transparent graduated burette provides visualization of the flow and clarity of the CSF, and allows for volumetric readings to be made prior to fluid entering the drainage bag.
0
-
Hermetic™ Plus
Integra
Hermetic™ Plus External CSF Drainage System with Anti-Reflux Valve and Needleless Injection Site
0
-
MoniTorr™
Integra
MoniTorr™ ICP External CSF Drainage and Monitoring System
0
-
MoniTorrTM
Integra
MONITORR ICPThe MoniTorr ICP External CSF Drainage and Monitoring System provides a simple to use, closed system for the drainage of cerebrospinal fluid (CSF) from ventricles of the brain or the lumbar subarachnoid space to a drainage bag. The system may be used with a pole mounted assembly that allows for simple, quick, and accurate alignment with the patient and secure, positive or negative pressure level setting. The system has also been designed to provide for ease of patient transport through a compact design and an antimicrobial hydrophobic vent feature that resists occlusion. Common features include a calibrated graduated burette, a drainage bag, sampling/aspiration sites, and an increased green stripe pressure tubing.
0
-
Integra® Pole Mount External CSF Drainage System
Integra
The External CSF Drainage Systems provide a sterile fluid path resistant to microbial particles. The systems are used to drain cerebrospinal fluid (CSF) from the ventricles of the brain of the lumbar subarachnoid space to a drainage bag. System components facilitate CSF drainage, fluid injection, CSF sampling and intracranial pressure (ICP) monitoring.
0
-
Hermetic™
Integra
Hermetic™ Hermetic Plus External CSF Drainage System