RevMed
Home/Specialty/Ophthalmic/Tonometer, Ac-Powered

Tonometer, Ac-Powered

48 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
JEDMED
JEDMED INSTRUMENT COMPANY
TONOMETER NON-CONTACT HORUS
0
-
Probes for HOME
ICARE FINLAND OY
Sales package 50pcs
0
-
Non-contact Tonometer HNT-1
Huvitz Co., Ltd.
The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye.
0
-
Non-contact Tonometer HNT-7000
Huvitz Co., Ltd.
The Non-Contact Tonometer is intended to be used to measure the intraocular pressure of the human eye.
0
-
OPTILASA
OPTILASA S.L.
0
-
OPTILASA
OPTILASA S.L.
0
-
Probes for HOME
ICARE FINLAND OY
Sales package 20pcs of TP022 probes
0
-
Probes for HOME
ICARE FINLAND OY
Single unit blister package
0
-
Icare tonometer probes
ICARE FINLAND OY
0
-
Icare ic100
ICARE FINLAND OY
The Icare ic100 tonometer is based on induction-based rebound method, which allows intraocular pressure (IOP) to be measured accurately, rapidlyand without an anesthetic. The Icare ic100 tonometer is intended to be used for the measurement of intraocular pressure of the human eye.
0
-
Icare HOME tonometer
ICARE FINLAND OY
0
-
Icare TA01i
ICARE FINLAND OY
The Icare tonometer is used in the diagnosis, follow up and screening of glaucoma. It is based on induction-based rebound method, which allows intraocular pressure (IOP) to be measured accurately, rapidly and without an anesthetic.The Icare tonometer TA01i is intended to be used for the measurement of intraocular pressure of the human eye.
0
-
Pulsair Desktop (complete)
KEELER LIMITED
0
-
Pulsair Intellipuff
KEELER LIMITED
0
-
NON CONTACT TONOMETER
NIDEK CO.,LTD.
The NON CONTACT TONOMETER Model NT-530 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology.
0
-
NON CONTACT TONOMETER
NIDEK CO.,LTD.
The NON CONTACT TONOMETER Model NT-510 is designed for non-contact tonometry measurement. The non-contact tonometry function measures the intraocular pressure without contacting the eye. Tonometry is performed for screening of glaucoma, and for preoperative examination and postoperativecare in ophthalmology.
0
-
AUTO REF/KERATO/TONOMETER
NIDEK CO.,LTD.
AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye.
0
-
KOWA KT-800
KOWA COMPANY,LTD.
The Kowa KT-800 is indicated for measuring intraocular pressure without contacting the eye to aid in the screening and diagnosis of glaucoma.
0
-
NON-CONTACT TONOMETER
TOMEY CORPORATION.
220V
0
-
NON-CONTACT TONOMETER
TOMEY CORPORATION.
The NON-CONTACT TONOMETER FT-1000 is a tonometer designed using a non-contact measurement system. Air puff gently measures the intraocular pressure of the human eye.
0
-
NON-CONTACT TONOMETER
TOMEY CORPORATION.
The NON-CONTACT TONOMETER FT-100 is a tonometer designed using a non-contact measurement system Air puff gently measures the intraocular pressure of the human eye.
0
-
NON-CONTACT TONOMETER
TOMEY CORPORATION.
0
-
COMPUTERIZED TONOMETER CT-80
TOPCON CORPORATION
0
-
CANON INC.
CANON INC.
0
-
Corvis STL
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
The Corvis® ST is a non-contact tonometer equipped with an opticalPachymetry function.The Corvis® ST measures intraocular pressure without contact with the eyeby applying an air puff to the eye. During the air puff the eye getsilluminated by a 9 mm slit through the apex and a built-in high-speedcamera records the movement of the eye with more than 4000 images persecond.The high-speed camera uses a sequence of 140 Scheimpflug images of thecornea which are analyzed by a built-in computer.Intra ocular pressure is determined by the detection of the applanationmoments of the cornea.
0
-
DIPLOMAT Def.
SIGNUS Medizintechnik GmbH
An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery.
0
-
DIPLOMAT Def.
SIGNUS Medizintechnik GmbH
An orthopedic manual surgical instrument is a nonpowered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery.
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX220 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: keratometer, corneal topographer, tonometer,and pachymeter and retro illumination
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX120 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefracter keratometer, corneal topographer, tonometer, pachymeter and retro illumination.
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX118 is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefracter keratometer, corneal topographer, pachymeter and retro illumination.
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX130 is a multi-function diagnostic device combining wavefront aberometer, corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the centralcornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil ImageImage of the cornea relative to the iris
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX120+ is a multi-function diagnostic device combining corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation. Photographing the eye and taking images of the eye to evaluate the thickness of the cornea.Analysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT)Meibomian glands imagingEvaluation of tear meniscus height
0
-
VISIONIX
LUNEAU TECHNOLOGY OPERATIONS
The VX130+ is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefractometer, keratometer, corneal topographer, tonometer, multi-slit pachymeter, tear-film analyzer , and retro illumination.The VX130+ is a multi-function diagnostic device combining wavefront aberometer, cornealtopographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the central cornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil ImageImage of the cornea relative to the irisAnalysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT)Meibomian glands imagingEvaluation of tear meniscus height
0
-
WAVE ANALYZER MEDICA 700
ESSILOR INTERNATIONAL
The WAM700 is a multifunctional ophthalmic device. The machine is a combination of 5 technologies :- Shack Hartmann technology : to measure both low and high order aberrations of the eye, to measure refraction.- Placido disks : for keratometry and for corneal topography measurement.- Non-contact tonometer.- Scheimpflug image : for anterior chamber analysis (pachymetry, irido corneal angle).- Retro illumination : for detection of opacity.Measurement is fully automatic using image processing software and fully automated motors for centering and focusing. The machine includes a fixation target with automatic fogging for accommodation control.
0
-
Eli Ezer
U.S. OPHTHALMIC, L.L.C.
Non-Contact Tonometer
0
-
LuxVision
U.S. OPHTHALMIC, L.L.C.
0
-
LuxVision
U.S. OPHTHALMIC, L.L.C.
0
-
VISUPLAN 500
REICHERT, INC.
AC-powered, non-contact tonometer indicated for measuring intraocular pressure (IOP) to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Ocular Response Analyzer® G3
REICHERT, INC.
AC-powered, non-contact tonometer intended to measure the intraocular pressure of the eye and the biomechanical response of the cornea for the purpose of aiding in the diagnosis and monitoring of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Reichert® 7CR Auto Tonometer
REICHERT, INC.
AC -powered non-contact tonometer intended to measure the intraocular pressure of the eye, taking into consideration the biomechanical response of the cornea. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
PT100 Portable Non-Contact Tonometer
REICHERT, INC.
Handheld, battery-powered, non-contact tonometer intended to measure the intraocular pressure of the eye. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Reichert® 7 Auto Tonometer
REICHERT, INC.
AC powered, non-contact tonometer indicated for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.