Exerciser, Powered
Main Filters
Exerciser, Powered
ACCELERATED CARE PLUS CORP | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
A007-533 | 0 | - |
ARETECH, LLC | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
BG-001 | 0 | - | ||
LU-001 | 0 | - | ||
ZG3D-001 | 0 | - |
BIODEX MEDICAL SYSTEMS, INC. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
950-146 | 0 | - | ||
950-148 | 0 | - | ||
950-240 | 0 | - | ||
950-570 | 0 | - |
CHARIOT INNOVATIONS INC | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
MCE04 | 0 | - | ||
MCE04SUAC | 0 | - | ||
MCE04SUAG | 0 | - | ||
MCE04SUCC | 0 | - | ||
MCE04SUCG | 0 | - |
COMPASS HEALTH BRANDS CORP. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
5100D021 | 0 | - | ||
5100D024 | 0 | - | ||
5100D028 | 0 | - | ||
5100D031 | 0 | - | ||
5100D032 | 0 | - | ||
5100D037 | 0 | - | ||
5100D038 | 0 | - | ||
5100D039 | 0 | - | ||
5100D040 | 0 | - | ||
5100D041 | 0 | - | ||
DQAPT | 0 | - |
DIH TECHNOLOGY INC. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
SG360 | 0 | - | ||
SGA360 | 0 | - | ||
SGAS1000 | 0 | - |
DJO, LLC | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
20707 | 0 | - |
Guangzhou Longest Medical Technology Co., Ltd. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
LGT-5100D | 0 | - |
Guangzhou Pinzhi Medical Technology Co., LTD | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
PZ-5201 | 0 | - | ||
PZ-5202 | 0 | - | ||
PZ-5203 | 0 | - | ||
PZ-5204 | 0 | - |
HILL LABORATORIES CO. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
SAVE Motion Chair | 0 | - |
JK-Products GmbH | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
JK 158 / BA VBR | 0 | - | ||
JK 194/RV32-0 VBR | 0 | - | ||
JK 194/RV32-10 VBR | 0 | - | ||
JK 98 / BA VBR E | 0 | - | ||
JK 98 / RV 30-0 VBR E | 0 | - |
Lifeward CA, Inc. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
Neo | 0 | - | ||
Neo+ | 0 | - |
medica - Medizintechnik GmbH | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
01.XX.XX | 0 | - | ||
01.YY.XX | 0 | - | ||
02.XX.XX | 0 | - | ||
03.XX.XX | 0 | - | ||
A000-533 | 0 | - | ||
A004-419 | 0 | - |
Titin Km Biomedical Corp. | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
A1-0000 | 0 | - |
tyromotion GmbH | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
5 | 0 | - | ||
6 | 0 | - |
154 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
PABLO
tyromotion GmbH
PABLO is a modern therapy device for the rehabilitation of patients suffering from motoric dysfunctions; it is primarily used for neurological rehabilitation purposes.
0
-
TYMO
tyromotion GmbH
TYMO is a monitoring and therapy device for the rehabilitation of patients suffering from motoric dysfunctions; it is primarily used for neurological rehabilitation purposes.
0
-
Active Passive Trainer For Upper And Lower Limbs
Guangzhou Pinzhi Medical Technology Co., LTD
0
-
Active Passive Trainer For Upper And Lower Limbs
Guangzhou Pinzhi Medical Technology Co., LTD
0
-
Active Passive Trainer For Upper And Lower Limbs
Guangzhou Pinzhi Medical Technology Co., LTD
0
-
Active Passive Trainer For Upper And Lower Limbs
Guangzhou Pinzhi Medical Technology Co., LTD
0
-
Active Passive Trainer for Upper and Lower Limbs
Guangzhou Longest Medical Technology Co., Ltd.
0
-
OmniCycle Connect
medica - Medizintechnik GmbH
The system is a therapeutic device for circular passive, assistive or active movement of the upper and lower extremities. The transition from passive to active therapy is seamless. The system is used in a seated position, e.g. in a wheelchair or suitable therapy chair.The movement is managed by two drive units which differentiate in upper and lower extremities. The drive unit for lower extremities is limited in extent by the selected crank radius. The drive unit for upper extremities is limited to one crank radius. Both drive units are never moved simultaneously.The therapy drive units for leg and arm do drive a supportive accessory for legs (footrests) and arms (therapy grips, arm support or arm rest) in a circular motion. The different accessories are interchangeable by the operator.With the user interface the operator is able to select a training type (upper extremity or lower extremity training) which heads for related therapy drive unit.The medical device guarantees a non-slip and tilt resistant stand during the training preparation of the device as well as during the training. The device can be easily transported to different places of use or storage by means of castors and transport belt.The interfaces of the upper drive unit are designed in such a way that other accessory options are easy to attach. The requirements for the use of these accessories are derived from the degree of disability of the user.The training of the upper extremities should be possible as an option and does not have to be present as a matter of principle.
0
-
THERA-Trainer toro
medica - Medizintechnik GmbH
The system is a therapeutic device for circular passive, assistive or active movement of the upper and lower extremities. The transition from passive to active therapy is seamless. The system is used in a seated position, e.g. in a wheelchair or suitable therapy chair.The movement is managed by the therapy drive unit and is limited in extent by the selected crank radius. The upper and lower extremities are driven by the same drive unit. The extremity arms and legs are never moved simultaneously by the therapy drive unit.The therapy drive unit drives a support device for legs (footrest) and arms (therapy grips) in a circular motion. The different positioning devices should be easily interchangeable by the operator.With the base frame and the electronic pivoting therapy drive unit, the therapy drive unit can be positioned individually in front of the user. Suitable devices guarantee a non-slip and tilt resistant stand during the training preparation of the device as well as during the training. The device can be easily transported to different places of use or storage by means of castors.The interfaces of the arm/leg accessory are designated in such a way that options from the current CL product portfolio can be used. This is intended to provide optimum protection for the user. The requirements are derived from the degree of disability of the user.Especially in clinics the point hygiene is very important, so an easy disinfection and cleaning is possible.
0
-
THERA-Trainer tigo
medica - Medizintechnik GmbH
The system is a therapeutic device for circular passive, assistive or active movement of the upper and lower extremities. The transition from passive to active therapy is seamless. The system is used in a seated position, e.g. in a wheelchair or suitable therapy chair. The movement is managed by two drive units which differentiate in upper and lower extremities. The drive unit for lower extremities is limited in extent by the selected crank radius. The drive unit for upper extremities is limited to one crank radius. Both drive units are never moved simultaneously. The therapy drive units for leg and arm do drive a supportive accessory for legs (footrests) and arms (therapy grips, arm support or arm rest) in a circular motion. The different accessories are interchangeable by the operator. With the user interface the operator is able to select a training type (upper extremity or lower extremity training) which heads for related therapy drive unit. The medical device guarantees a non-slip and tilt resistant stand during the training preparation of the device as well as during the training. The device can be easily transported to different places of use or storage by means of castors and transport belt. The interfaces of the upper drive unit are designed in such a way that other accessory options are easy to attach. The requirements for the use of these accessories are derived from the degree of disability of the user. The training of the upper extremities should be possible as an option and does not have to be present as a matter of principle.
0
-
SafeGait Active 360 Dynamic Mobility Trainer
DIH TECHNOLOGY INC.
SafeGait Active 360 system (Model SGA360) is designed to assist a patient with walking/balance impediments to exercise and/or regain normal gait. SafeGait Active 360 system tethers patients with a dedicated harness hanging from a powered pneumatic braking device on the overhead aluminum rails moved by pulling force from the patient. SafeGait Active 360 system reduces clinician’s workload when helping patients to exercise or relearn the gait in a safe 3D environment. SafeGait Active 360 system shall only be operated by trained clinicians, therapists or DIH staff.
0
-
SafeGait Active Dynamic Mobility Trainer
DIH TECHNOLOGY INC.
SafeGait Active S1000 system (Model SGAS1000) is designed to assist a patient with some impediments in walking/balance to exercise and/or to regain normal gait. SafeGait Active S1000 system tethers patients with a dedicated harness hanging from a powered pneumatic braking device on the overhead steel rails moved by pulling force from the patient. SafeGait Active S1000 system reduces clinician’s workload when helping patients to exercise or relearn the gait in a safe 3D environment. SafeGait Active S1000 system shall only be operated by trained clinicians, therapists or DIH staff.
0
-
SafeGait 360 Balance and Mobility Trainer
DIH TECHNOLOGY INC.
SafeGait 360 system (Model SG360) is a body weight support system designed to assist a patient with a walking/balance disability to regain mobility via exercise and gait training. SafeGait 360 system tethers patients with a dedicated harness hanging from a powered device running on the overhead aluminum rails to offload the patient’s weight to various levels configurable via a computer or a handheld device. SafeGait 360 system reduces clinician’s workload when helping patients to exercise or relearn the gait in a safe 3D environment. SafeGait 360 system shall only be operated by trained clinicians, therapists or DIH staff.
0
-
Humero Tech
Titin Km Biomedical Corp.
The Humero Tech C1 has been developed as a solution for the current limitations with shoulder rehabilitation. The C1 is a seated apparatus capable of completing a vast number of shoulder rehabilitation and strengthening exercises. This device has the capability to be utilized in low level rehabilitation and strengthening progressing to more functional and dynamic activities. The Humero Tech C1 has an intended use of assisting with improving the strength, active range of motion, and motor control of the shoulder complex. Furthermore, the indications for use will be any individual suffering from a shoulder pathology, including postoperative status, or when a deficit in power is noted. The device collects data and tracks range of motion to evaluate progress over time.
0
-
OmniCycle Elite 7 Inch Screen Motorized Therapeutic Exercise System
ACCELERATED CARE PLUS CORP
Motorized therapy cycle with a 7 inch screen that can connect to the OmniTour system
0
-
AlterG Anti-Gravity Treadmill
Lifeward CA, Inc.
The Neo+ Anti-Gravity Treadmill is intended to be an entry-level product used in a clinical setting for standing, walking, or running in place for rehabilitation, or conditioning for individuals who may require or benefit from the use of body weight support
0
-
AlterG Anti-Gravity Treadmill
Lifeward CA, Inc.
The Neo Anti-Gravity Treadmill is intended to be an entry-level product used in a clinical setting for standing, walking, or running in place for rehabilitation, or conditioning for individuals that may require or benefit from the use of body weight support
0
-
Luminaire BWS Treadmill System
ARETECH, LLC
Luminaire is a robotic body-weight support system fixed above a slat-belt treadmill. The system provides precise levels of dynamic body-weight support to the patient as they walk on the treadmill, while simultaneously preventing falls. Clinician seating and footplates can be used for situations where manual-assisted ambulation is desired. The Luminaire System is intended to assist subjects who have experienced neurological and orthopedic injuries as they practice ambulating on a treadmill. Luminaire should never be used to lift subjects and should never be connected to inanimate objects. Luminaire should only be operated by therapists and trained healthcare professionals who have read and understand the instructions for use and have passed the Luminaire training competency exam conducted by an Aretech trainer or a certified staff trainer.
0
-
ZeroG 3D 3-Dimensional BWS System
ARETECH, LLC
ZeroG 3D is a robotic body-weight support system which automatically tracks patients as they move freely in any direction. The dynamic body-weight support offloads a percentage of the patient’s weight as they perform activities in a full 3-dimensional workspace, while the advanced fall protection provides the highest level of safety. The ZeroG 3D System is intended to assist subjects who have experienced neurological and orthopedic injures as they practice therapeutic activities related to walking and balance activities. ZeroG 3D can also be used to train subjects ambulating on a treadmill. ZeroG 3D should never be used to lift and transport subjects and should never be connected to inanimate objects. ZeroG 3D should only be operated by therapists and trained healthcare professionals who have read and understand the instructions for use and have passed the ZeroG 3D training competency exam conducted by an Aretech trainer or a certified staff trainer.
0
-
BabyG Early Mobilization System
ARETECH, LLC
The BabyG Early Mobilization System is a robotic body-weight support system which automatically tracks patients as they move freely in any direction. The dynamic body-weight support offloads a percentage of the patient’s weight as they perform activities in a full 3-dimensional workspace, while the advanced fall protection provides the highest level of safety. The BabyG System is intended to assist subjects weighing 50 pounds or less as they practice therapeutic activities related to walking and balance activities. BabyG should never be used to lift and transport subjects and should never be connected to inanimate objects. BabyG should only be operated by therapists and trained healthcare professionals who have read and understand the instructions for use and have passed the BabyG training competency exam conducted by an Aretech trainer or a certified staff trainer.