RevMed
Home/Brands/C4 IMAGING, LLC

C4 IMAGING, LLC

7 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Available
Starting At
Name
Company Name
Description
0
-
Nova 10 Fiducial Marker
C4 IMAGING, LLC
0
-
Nova 5
C4 IMAGING, LLC
The Fiducial Marker consists of a sealed polyether ether ketone (PEEK) polymer capsule containing a solution of up to 1.0% cobalt chloride and up to 2.0% N-Acetyl cysteine, in a ratio of 1:2. Zirconium oxide is sealed within the device. The length of the polymer capsule is between 5.5 mm and 10.0 mm, and the diameter is 1.0 mm. It is loaded in an implant needle and sterilized with Ethylene Oxide.
0
-
Nova 5
C4 IMAGING, LLC
The Fiducial Marker consists of a sealed polyether ether ketone (PEEK) polymer capsule containing a solution of up to 1.0% cobalt chloride and up to 2.0% N-Acetyl cysteine, in a ratio of 1:2. Zirconium oxide is sealed within the device. The length of the polymer capsule is between 5.5 mm and 10.0 mm, and the diameter is between 0.9 mm and 1.2 mm.
0
-
HDR MRI Lumen Marker
C4 IMAGING, LLC
The HDR MRI Lumen Marker is a sealed high-density polyethylene (HDPE) tube containing a cobalt chloride N-Acetylcysteine saline solution. The HDPE tube is up to 350.0 mm in length and 1.0 mm in diameter, with the distal 19.0 mm of the tube accommodating a HDPE sealing plug. The distal end of the device is provided with an attached HDPE end-cap for handling. This end cap is approximately 3.0 mm in length. The HDR MRI Lumen Marker is an accessory to remote controlled high dose rate (HDR) radionuclide applicator systems and facilitates the identification of lumens within MRI compatible HDR brachytherapy applicators.
0
-
Sirius MRI Marker NS
C4 IMAGING, LLC
The SIRIUS MRI Marker NS is a component device indicated as an accessory for use in conjunction with brachytherapy seed carrier sleeves and radionuclide brachytherapy sources containing one of the following isotopes: Iodine 125 (125I), Palladium 103 (103Pd) or Cesium 131 (131Cs). It is indicated for permanent interstitial implantation in the prostate of patients with confirmed prostatic malignancy.
0
-
Sirius MRI Marker
C4 IMAGING, LLC
The SIRIUS MRI Marker is a component device indicated as an accessory for use in conjunction with brachytherapy seed carriersleeves and radionuclide brachytherapy sources containing one of the following isotopes: Iodine 125 (125I), Palladium 103(103Pd) or Cesium 131 (131Cs). It is indicated for permanent interstitial implantation in the prostate of patients with confirmedprostatic malignancy.
0
-
Sirius MRI Marker
C4 IMAGING, LLC
The SIRIUS MRI Marker is a component device indicated as an accessory for use in conjunction with brachytherapy seed carrier sleeves and radionuclide brachytherapy sources containing one of the following isotopes: Iodine 125 (125I), Palladium 103 (103Pd) or Cesium 131 (131Cs). It is indicated for permanent interstitial implantation in the prostate of patients with confirmed prostatic malignancy.