ECOTRON
- Extraoral source x-ray systemBattery Input: 22.2V, 1AOutput Rating: 210WkVp: 70kVmA: 3mASec: 0.02 - 0.5sec
0
-
ECOTRON
1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5.0kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch
0
-
ECOTRON
1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 15~40mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch
0
-
ECOTRON
1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 2.4kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 16~30mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch
0
-
ECOTRON
LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV) KVP range: 40~150kVpmA range: 10~1000mAmAs Range: 0.1~500mAs
0
-
ECOTRON
LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 68kW(800mA@85kV, 640mA@106kV, 400mA@150kV) KVP range: 40~150kVpmA range: 10~800mAmAs Range: 0.1~500mAs
0
-
ECOTRON
LINE POWER RATING: 400V3~, 50/60HzOUTPUT RATING: 52kW(640mA@81kV, 400mA@130kV, 320mA@150kV) KVP range: 40~150kVpmA range: 10~640mAmAs Range: 0.1~500mAs
0
-
ECOTRON
LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 40kW(500mA@80kV, 400mA@100kV, 320mA@125kV) KVP range: 40~125kVpmA range: 10~500mAmAs Range: 0.1~500mAs
0
-
ECOTRON
LINE POWER RATING: 230V, 50/60HzOUTPUT RATING: 32kW(400mA@80kV, 320mA@100kV, 250mA@125kV) KVP range: 40~125kVpmA range: 10~400mAmAs Range: 0.1~400mAs
0
-
ECOTRON
1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 5kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Image Intensifier - E5830SD-PA4(TOSHIBA), 9inch7. Camera - CCD, Resolution: 1K X 1K
0
-
ECOTRON
Input Power: 200V~240V, 50/60HzOutput Power: 5.0kWKVP range: 50~110kVmA range: 20~100mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU
0
-
ECOTRON
Input Power: 200V~240V, 50/60HzOutput Power: 4.0kWKVP range: 50~110kVmA range: 20~80mAmAs range: 0.4~100mAsX-ray Tube: OX/110-15Focal Sport: 1.8 x 1.8mmTarget Angle: 15 degreesAnode heat storage: 42kHU
0
-
ECOTRON
Input Power: 200V~240V, 50/60HzOutput Power: 3.2kWKVP range: 40~100kVmA range: 25~60mAmAs range: 0.4~100mAsX-ray Tube: D-205BFocal Sport: 2.0 x 2.0mmTarget Angle: 20 degreesAnode heat storage: 40kHU
0
-
ECOTRON
Input Power: 110V~120V, 50/60HzOutput Power: 2.8kWKVP range: 40~120kVmA range: 14~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU
0
-
ECOTRON
Input Power: 110V~120V, 50/60HzOutput Power: 2.4kWKVP range: 40~100kVmA range: 16~40mAmAs range: 0.4~100mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU
0
-
ECOTRON
Input Power: 110V~120V, 50/60HzOutput Power: 1.6kWKVP range: 40~90kVmA range: 12~30mAmAs range: 0.4~32mAsX-ray Tube: D-125Focal Sport: 1.2 x 1.2mmTarget Angle: 16 degreesAnode heat storage: 50kHU