RevMed
Home/Brands/G21 SRL

G21 SRL

84 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
2
$120.00
V-STEADY
G21 SRL
Radiopaque Bone Cement for vertebral consolidation
0
-
SpaceFlex Acetabular Cup
G21 SRL
The SpaceFlex Acetabular Cup consists of disposable cement spacer molds indicated for use to mold a temporary Acetabular cup replacement for skeletally mature patientsundergoing a two-stage procedure due to a septic process.The temporary prosthesis is molded using low viscosity antibiotic polymethylmethacrylate bone cement (G3A 40 bone cement) and positioned into the acetabular cavity following removal of the existing acetabular and femoral components and radical debridement.The molded acetabular cup is intended for use in conjunction with systemic antimicrobial antibiotic therapy (standard treatment approach to an infection). The molded temporary Acetabular cup prosthesis is indicated for an implantation period of 180 days or less. Because of inherent mechanical limitations of the device material(Bone Cement), the molded temporary prosthesis is only indicated for patients who will consistently use traditional mobility assist devices (e.g., crutches, walkers) throughout the implant period.
0
-
SpaceFlex Knee
G21 SRL
Orthopedic bone cement modular spacer for temporary knee prosthesis
0
-
SpaceFlex Knee
G21 SRL
0
-
SpaceFlex Knee
G21 SRL
0
-
SpaceFlex Hip
G21 SRL
Disposable custom modular spacer mold
0
-
SpaceFlex Hip
G21 SRL
Disposable custom modular spacer mold
0
-
SpaceFlex Hip
G21 SRL
Disposable custom modular spacer mold
0
-
Winch Kyphoplasty ( 20 mm) 11 Gauge Balloon Catheter
G21 SRL
Kyphoplasty Balloon Catheter
0
-
Winch Kyphoplasty ( 15 mm) 11 Gauge Balloon Catheter
G21 SRL
Kyphoplasty Balloon Catheter
0
-
OrthoSteady G
G21 SRL
Bone Cement
0
-
FLEX DRILL 13G
G21 SRL
Curette with curved distal end used to create a cavity inside the vertebra.
0
-
Winch Kyphoplasty ( 20 mm) 11 Gauge Balloon Catheter
G21 SRL
Kyphoplasty Balloon Catheter
0
-
Winch Kyphoplasty ( 15 mm) 11 Gauge Balloon Catheter
G21 SRL
Kyphoplasty Balloon Catheter
0
-
SpaceFlex Hip Instrument Kit
G21 SRL
SpaceFlex Hip Instrument Kit is intended to be used in combination with SpaceFlex Hip to mold temporary prosthesis.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
SpaceFlex Shoulder
G21 SRL
Disposable cement spacer molds with metal reinforcement stem are indicated for use to mold atemporary hemi- shoulder replacement for skeletally mature patients undergoing a two-stagerevision procedure due to a septic process.The temporary prosthesis is molded using low viscosity polymethylmethacrylate bonecement and inserted into the humeral medullary canal and glenoid cavity of the shoulderfollowing removal of the existing humeral and glenoideal cavity implants and debridement.SpaceFlex Shoulder should only be used with G3A low-viscosity bone cement.The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy(standard treatment approach to an infection).The hemi-shoulder prosthesis made from the SpaceFlex Shoulder disposable cement molds isnot intended for use more than 180 days, at which time it must be explanted and permanentdevices implanted or another appropriate treatment performed (e.g. resection arthroplasty,fusion, etc.).Due to the inherent mechanical limitations of the hemi-shoulder prosthesis material (lowviscosity polymethylmethacrylate), the temporary hemi-shoulder prosthesis is only indicatedfor patients who will consistently follow activity limitation throughout the implant period.The device can exclusively be used by competent healthcare personnel who has completescientific and anatomical knowledge.
0
-
G1 40 Radiopaque Bone Cement
G21 SRL
Radiopaque Bone Cement
0
-
V-FAST
G21 SRL
Radiopaque Bone Cement for vertebral consolidation
0
-
G3A 40 Bone Cement
G21 SRL
0
-
G3 40 Radiopaque Bone Cement
G21 SRL
Radiopaque Bone Cement
2
Best Offer
PicoMix V
G21 SRL
Mixing System and Delivery Syringes
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
Arthrex Bone Cement Syringe Gun, Disposable
G21 SRL
0
-
Arthrex Bone Cement Mixing Syringe
G21 SRL
0
-
Arthrex Bone Cement Closed Mixing Bowl
G21 SRL
0
-
Arthrex Bone Cement MV
G21 SRL
0
-
Arthrex Bone Cement HV
G21 SRL
0
-
BRAVO HV+G
G21 SRL
0
-
BRAVO MV+G
G21 SRL
0
-
BRAVO MV
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
CeMend Shoulder Spacer Mold
G21 SRL
0
-
Arthrex Bone Cement Syringe Gun, Disposable
G21 SRL
0
-
Arthrex Bone Cement Closed Mixing Bowl
G21 SRL
0
-
Arthrex Bone Cement MV w/G
G21 SRL
0
-
Arthrex Bone Cement MV
G21 SRL
0
-
Arthrex Bone Cement HV w/G
G21 SRL
  1. 1
  2. 2
Next