Flex Coils Pediatric Stabilizer
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
0
-
3T 16ch Flex SPEEDER Medium
NEOCOIL, LLC
The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis. head, neck, and spine. The system is compatible with 20, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction.
0
-
3T 16ch Flex SPEEDER Large
NEOCOIL, LLC
The NeoCoil 3T l6ch Flex SPEEDER Coils are a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis. head, neck, and spine. The system is compatible with 20, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction.
0
-
1.5T GEM Flex Pediatric Interface, P-Connector
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations.
0
-
Communication Control
NEOCOIL, LLC
The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals.
0
-
Pen Panel Transmitter Box
NEOCOIL, LLC
The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals.
0
-
Stand-Alone Wireless Patient Alert
NEOCOIL, LLC
The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals.
0
-
Stand-Alone Wireless Audio Headphones
NEOCOIL, LLC
The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals.
0
-
Pediatric SPEEDER Stabilizer
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi
0
-
1.5T 16ch Flex SPEEDER Medium
NEOCOIL, LLC
The NeoCoil 1.5T l6ch Flex SPEEDER is a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine. The system is compatible with 2D, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction.
0
-
1.5T 16ch Flex SPEEDER Large
NEOCOIL, LLC
The NeoCoil 1.5T l6ch Flex SPEEDER is a receive-only phased array coil system designed to provide high resolution imaging for the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine. The system is compatible with 2D, 3D, parallel and isotropic imaging, as well as, coil signal intensity correction.
0
-
3.0T GEM Flex Interface, P-Connector
NEOCOIL, LLC
0
-
3.0T GEM Flex Coil 16-L Array
NEOCOIL, LLC
0
-
3.0T GEM Flex Coil 16-M Array
NEOCOIL, LLC
0
-
3.0T GEM Flex Coil 16-S Array
NEOCOIL, LLC
0
-
1.5T GEM Flex Interface, HD-Connector
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation.
0
-
1.5T GEM Flex Coil 16-L Array
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation.
0
-
1.5T GEM Flex Coil 16-M Array
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation.
0
-
1.5T GEM Flex Coil 16-S Array
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations. The NecCoil 1 .5T GEM Flex Coil is tuned to receive RF frequency corresponding to the proton precession in a 1.5 tesla magnetic field, which is governed by the Larmor equation.
0
-
1.5T GEM Flex Interface, P-Connector
NEOCOIL, LLC
The NeoCoil 1 .5T GEM Flex Coil is a receive-only phased array coil system for imaging the upper and lower extremities, chest, abdomen, pelvis, head, neck, and spine in pediatric and adult populations.
0
-
3T 8ch Shoulder Coil
NEOCOIL, LLC
The NeoCoil 3.OT 8-Channel Shoulder Array Coil is a multi-element phased arrayreceive only coil used for obtaining diagnostic images of the shoulder in MagneticResonance Imaging Systems. Compared to predicate devices, the submitteddevice offers easier patient setup and greater SNR due to its compatibility with3.OT MRI scanners.The submitted device consists of semi-flexible foam covered housing, consistingof eight antennas. The antennas are uniquely positioned with the appropriateoverlap to cancel out mutual coupling effects from adjacent antennas ordecoupled from an adjacent antenna using a transformer. Pre-amplifierdecoupling reduces any remaining decoupling between the antennas.The coil is held in place over the imaging area via a cross body strap. A systeminterface cable connects to the coil at the top of the housing. The flexible foamcovered housing along with the body strap enable the proper positioning on thepatient before laying down and holds the coil in place while scanning is beingperformed.To ensure safety, each antenna is equipped with active and passive transmitdecoupling circuits. Active decoupling is achieved via diodes that receive signalsfrom the scanner to turn the coil to a high impedance state during system RFtransmit. Crossed diodes are installed on each antenna acting as passiveswitches. These passive switches provide additional safety in case the activecircuitry does not receive signal from the scanner.
0
-
1.5T 8ch Shoulder Coil
NEOCOIL, LLC
The NeoCoil 1 ST 8-Channel Shoulder Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the shoulder in Magnetic Resonance Imaging Systems. Compared to predicate devices, the submitted device offers greater SNR due to its unique eight channel layout and a larger field-of-view due to the antenna layout.
0
-
3T 32Ch Torso Coil - Posterior
NEOCOIL, LLC
The NeoCoil 3.OT 32-Channel Torso Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the chest,abdomen, and pelvic area in Magnetic Resonance Imaging Systems. The coil consists of 2 antenna arrays; a posterior and an anterior. The posteriorarray contains 17 elements to achieve 16 channels and is enclosed in a rigid housing. The anterior array also contains 17 elements to achieve the later 16 channels but is enclosed in a flexible housing. The coil is wrapped around the patient's torso with hook and loop straps. The NeoCoil 3.0T 32-Channel Torso Array Coil is for use with the GE S.OT HD Series MR System (K052293)
0
-
3T 32Ch Torso Coil - Anterior
NEOCOIL, LLC
The NeoCoil 3.OT 32-Channel Torso Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the chest, abdomen, and pelvic area in Magnetic Resonance Imaging Systems. The coil consists of 2 antenna arrays; a posterior and an anterior. The posterior array contains 17 elements to achieve 16 channels and is enclosed in a rigid housing. The anterior array also contains 17 elements to achieve the later 16 channels but is enclosed in a flexible housing. The coil is wrapped around the patient's torso with hook and loop straps. The NeoCoil 3.0T 32-Channel Torso Array Coil is for use with the GE S.OT HD Series MR System (K052293)
0
-
3T 6CH Carotid Coil
NEOCOIL, LLC
The NeoCoil 3.OT 6-Channel Carotid Array Coil is a multi-element phased array receive only coil used for obtaining diagnostic images of the carotid arteries andassociated vasculature from the sternal notch through the internal carotid arteries at the level of cervical vertebrae C1 in Magnetic Resonance Imaging Systems. Compared to predicate devices, the submitted device offers greater SNR due to its operating field strength of 3.0T, and a larger field-of-view due to the antenna layout.
0
-
Drape Pack, Biopsy, Breast Coil
NEOCOIL, LLC
0
-
Biopsy Grid Assembly, Pack, Breast Coil
NEOCOIL, LLC
0
-
32ch AIR Open Coil Suite, 1.5T
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
32ch AIR Open Coil Suite, 3.0T
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
1.5T 16ch Breast Coil
NEOCOIL, LLC
0
-
3T 16ch Breast Coil
NEOCOIL, LLC
0
-
1.5T AIR Open Head Anterior 16ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
1.5T AIR Open Neck Chest Anterior 7ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
1.5T AIR Open Head Neck Posterior 9ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
3.0T AIR Open Head Anterior 16ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
3.0T AIR Open Neck Chest Anterior 7ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).
0
-
3.0T AIR Open Head Neck Posterior 9ch
NEOCOIL, LLC
The 32Ch AIR Open Coil Suite is comprised of MRI receive-only phased array RF coils designed for clinically acceptable signal-to-noise ratio (SNR) and uniform coverage of the Head, Neck and Brachial Plexus anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The 32Ch AIR Open Coil Suite consists of the following arrays available in 1.5T and 3.0T field strengths:• AIR Open Head Neck Posterior 9ch• AIR Open Neck Chest Anterior 7ch• AIR Open Head Anterior 16chThe coils receive magnetic resonance signals generated in hydrogen nuclei (protons) in the Head, Neck and Brachial Plexus anatomy while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed by the MRI scanner into tomographic images of the Head, Neck and Brachial Plexus anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices. There are no accessories associated with the 32Ch AIR Open Coil Suite. Depending on the region of interest, the coils may be used in combination with the CIVCO RT Universal Couchtop™ MRI Overlay for compatible MR table(s) and associated patient immobilization devices (e.g., thermoplastic mask, straps provided with the MRI scanner).