REICHERT, INC.
Main Filters
22 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
CT100 Contact Tonometer
REICHERT, INC.
Non-active contact, applanation tonometer intended to measure intraocular pressure of the eye.
0
-
VISUPLAN 500
REICHERT, INC.
AC-powered, non-contact tonometer indicated for measuring intraocular pressure (IOP) to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
Ten (10) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
Three (3) replacement tip and membrane assemblies that attach to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Model 30™ Tip and Membrane Assembly for Pneumatonometer
REICHERT, INC.
One (1) replacement tip and membrane assembly that attaches to the Model 30 Pneumatonometer probe. Probe tip touches a patient's cornea during the measurement.
0
-
Ocu-Film +
REICHERT, INC.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
0
-
Ocu-Film +
REICHERT, INC.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
0
-
Ocular Response Analyzer® G3
REICHERT, INC.
AC-powered, non-contact tonometer intended to measure the intraocular pressure of the eye and the biomechanical response of the cornea for the purpose of aiding in the diagnosis and monitoring of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Xcel® 455 Slit Lamp
REICHERT, INC.
AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye.
0
-
iPac® Pachymeter
REICHERT, INC.
Handheld, battery-powered, ultrasound device intended to measure the thickness of the cornea. The device tip is touched to a patient's eye during the measurement.
0
-
Reichert® 7CR Auto Tonometer
REICHERT, INC.
AC -powered non-contact tonometer intended to measure the intraocular pressure of the eye, taking into consideration the biomechanical response of the cornea. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
Model 30 Pneumatonometer
REICHERT, INC.
AC powered contact tonometer intended for the measurement of intraocular pressure (IOP). The device is indicated for use as a screening /monitoring tool for glaucoma or when increased IOP is suspected.
0
-
Xcel® 255 Slit Lamp
REICHERT, INC.
AC powered biomicroscope that projects light into a patient's eye. The device is intended for use in examining the anterior segment of the eye, from the corneal epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma, which affect the structural properties of the anterior segment of the eye.
0
-
PSL Portable Slit Lamp
REICHERT, INC.
Handheld, battery powered, biomicroscope that projects light into a patient’s eye. It is intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosisof diseases or trauma which affect the structural properties of the anterior eye segment.
0
-
PT100 Portable Non-Contact Tonometer
REICHERT, INC.
Handheld, battery-powered, non-contact tonometer intended to measure the intraocular pressure of the eye. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
CT210 Contact Tonometer
REICHERT, INC.
Non-active, contact applanation tonometer intended to measure intraocular pressure of the eye.
0
-
Reichert® 7 Auto Tonometer
REICHERT, INC.
AC powered, non-contact tonometer indicated for measuring intraocular pressure to aid in the screening and diagnosis of glaucoma. An air puff is used to momentarily flatten a patient's cornea during the measurement.
0
-
Ocu-Film +
REICHERT, INC.
Single use tonometer tip cover used with Tono-Pen tonometers. Used to protect the transducer from dust and fluids, and helps protect patients from risk of cross-contamination.
0
-
Tono-Pen AVIA®
REICHERT, INC.
Handheld, battery-powered contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.
0
-
Tono-Pen® XL
REICHERT, INC.
Handheld, battery-powered, contact tonometer. Indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected.