0
-
Short Arm Flowmeter Mount Instant Flow Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
On/Off control of oxygen flow when using a resuscitator bag:For use with hyperinflation bag (not included) weighing 3 ounces to 4 pounds (90-1814 grams). The use of these sizes of bags typically range from neonatal, pediatric to adult care. The valves are intended to be used with a flowmeter (not included) which controls the flow of oxygen to the valve.On/off oxygen action is controlled by lifting/replacing the bag on the arm of the valve. Immediate oxygen flow is provided when bag is lifted from the arm (preventing personnel from having to turn oxygen on). Oxygen flow is stopped when bag is replaced.
0
-
Flowmeter Mount Instant Flow Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
On/Off control of oxygen flow when using a resuscitator bag:For use with hyperinflation bag (not included) weighing 3 ounces to 4 pounds (90-1814 grams). The use of these sizes of bags typically range from neonatal, pediatric to adult care. The valves are intended to be used with a flowmeter (not included) which controls the flow of oxygen to the valve.On/off oxygen action is controlled by lifting/replacing the bag on the arm of the valve. Immediate oxygen flow is provided when bag is lifted from the arm (preventing personnel from having to turn oxygen on). Oxygen flow is stopped when bag is replaced.
0
-
BE 195-A Adapter for Exhalation Valves
INSTRUMENTATION INDUSTRIES, INCORPORATED
This adapter connects to the exhalation valve for additional versatility.
0
-
BE 195-1522A Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 15mm I.D./22mm O.D. x 30mm I.D. Molded of polyetherimide. Reusable.
0
-
BE 193 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm I.D. Molded of polycarbonate. Reusable.
0
-
BE 192 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm O.D. Molded of polycarbonate. Reusable.
0
-
BE 191 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 22mm I.D. x 30mm I.D. Molded of polycarbonate. Reusable.
0
-
BE 190 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 22mm O.D. x 30mm O.D. Molded of polycarbonate. Reusable.
0
-
Manual Jet Ventilator
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 183-SUR-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation.
0
-
Manual Jet Ventilator
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 183-SUR Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation.
0
-
Manual Jet Ventilator
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 183-SU-12 Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation.
0
-
Manual Jet Ventilator
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 183-SU Manual Jet Ventilator is designed to provide trans-tracheal ventilation in specific emergency situations of upper airway obstructions. This system is used in conjunction with a trans-tracheal catheter, or cricothyrotomy needle, which is inserted through the cricothyroid membrane. Ventilation is accomplished by the manual, intermittent jetting of oxygen through the catheter for subsequent lung inflation.
0
-
BE 169-W Oxygen Tank Wrench
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 169-W Oxygen Tank Wrench fits the valve stem of E-cylinder-type oxygen tanks. Manufactured of zinc-plated steel.
0
-
BE 169 Oxygen Tank Wrench with Security Cable
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 169 Oxygen Tank Wrench with 12" Security Cable. Wrench fits the valve stem of E-cylinder-type oxygen tanks and is manufactured of zinc-plated steel. The security cable is Nylon-coated stainless steel.
0
-
BE 16-2 ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 16-2 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm I.D. x 18mm I.D./22mm O.D. x 18mm I.D./22mm O.D Reusable.
0
-
BE 150-5LF Test Lung
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 150-5LF Test Lung has a 22mm I.D. connection and a 750 ml capacity; Not made with natural rubber latex. Not for patient use.
0
-
BE 150-5G Test Lung
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 150-5G Test Lung has a 22mm I.D. connection and a 1 liter capacity; Not made with natural rubber latex. Not for patient use.
0
-
BE 149-1 Gauge Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The Instrumentation Industries, Inc. BE 149-1 Gauge Adapter has a 1/4" NPT connection on one end and a 15 mm I.D./22 mm O.D. connection on the other end for inspiratory monitoring.The BE 149-1 is designed to work with III Vacuum/Pressure Gauges and NIF Meters.The adapter is made of polycarbonate.
0
-
BE 148-6 Gauge Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The Instrumentation Industries, Inc. BE 148-6 Gauge Adapter has a 1/8" tubing connection on one end and a 15 mm I.D./22 mm O.D. connection on the other end for remote inspiratory monitoring.The BE 148-1 is designed to work with III Vacuum/Pressure Gauges and NIF Meters.The adapter is made of polycarbonate.
0
-
BE 148-5-3.5 Gauge Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 148-5-3.5 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gauges. The BE 148-5-3.5 is used to securely mount Gauges with a rear 1/4" NPT thread to medical equipment such as poles, incubators, ventilators, etc. The BE 148-5-3.5 gauge clamp works with equipment that requires a clamp having a 2-1/2" to 3-1/2" opening.
0
-
BE 148-5-2.5 Gauge Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 148-5-2.5 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gauges. The BE 148-5-2.5 is used to securely mount Gauges with a rear 1/4" NPT thread to medical equipment such as poles, incubators, ventilators, etc. The BE 148-5-2.5 clamp works with equipment that requires a clamp having a 1" to 2-1/2" opening.
0
-
BE 148-5-2 Gauge Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 148-5-2 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gauges. The BE 148-5-2 securely mounts Gauges with a rear 1/4" NPT thread to poles with 3/4" to 1-1/2" diameter.
0
-
BE 148-5-1 Gauge Clamp
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 148-5-1 Gauge Clamp is an accessory to the NS Series Vacuum/Pressure Gauges. The BE 148-5-1 securely mounts Gauges with a rear 1/4" NPT thread to 3/4" diameter poles.
0
-
Cuff Pressure Monitor Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 148-4 Cuff Pressure Monitor Adapter attaches to NS Series gauges with a 1/4" NPT fitting to create a Cuff Pressure Monitor. During ventilation, the NS Series Cuff Pressure Monitors are devices used to periodically monitor endotracheal or tracheostomy tube balloon pressure to assure an adequate seal between the tube and the tracheal wall.These devices are intended to be used by or on the order of a physician.
0
-
BE 148-1 Gauge Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The Instrumentation Industries, Inc. BE 148-1 Gauge Adapter changes 1/4" NPT connection to 1/8" small bore tubing connection.The BE 148-1 is designed to work with III Vacuum/Pressure Gauges and NIF Meters.The adapter is made of polycarbonate.
0
-
BE 145-2P Hose Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 145-2P Hose Connector: Dimensions - 15mm O.D. x tapered barb adapter
0
-
BE 145-2230P Hose Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 145-2230P Hose Connector: Dimensions - 22mm I.D/30mm O.D. x tapered barb adapter
0
-
BE 145-1522P Hose Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 145-1522P Hose Connector: Dimensions - 15mm I.D/22mm O.D. x tapered barb adapter
0
-
BE 142-A
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 142-A is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%. Objectives of PEEP therapy: 1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,2) aid in the prevention of atelectasis via aveolar stinting, 3) decrease in the inspired oxygen fraction (FiO2) is an advantage, 4) help in the stabilization of flail chest condition, and 5) monitor tidal volume by connecting a spirometer to the outlet port.
0
-
BE 142
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 142 is designed for use with ventilators, anesthesia machines, resuscitators, and other systems where PEEP or CPAP is required. A threshold-like resistance is applied after active exhalation. The PEEP valve prevents the exhalation pressure from dropping below a pre-determined value. PEEP ranges are adjustable from 3 to 20cm of water. Maximum PEEP can vary +/-10%. Objectives of PEEP therapy: 1) increase functional residual capacity by maintaining a positive pressure throughout the ventilatory cycle - improves gas distribution,2) aid in the prevention of atelectasis via aveolar stinting, 3) decrease in the inspired oxygen fraction (FiO2) is an advantage, 4) help in the stabilization of flail chest condition, and 5) monitor tidal volume by connecting a spirometer to the outlet port.
0
-
BE 139-105 Reducing Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Reducing Adapter for use in breathing/ventilator circuit. - 15mm O.D. x 15mm I.D./22mm O.D. Molded of polycarbonate. Reusable.
0
-
BE 139 Pressure Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 139 Pressure Adapter: Dimensions - Barbed port fits 3/16" I.D. tubing x 15mm I.D./22mm O.D. x 15mm O/D.
0
-
BE 131 One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 131 One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.The device includes a silicone rubber connector with 22mm I.D. Inlet.
0
-
BE 130-23BB One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130-23BB One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 130-22B One-way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130-22B One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 130 One-Way Valve
INSTRUMENTATION INDUSTRIES, INCORPORATED
The reusable BE 130 One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward the source.
0
-
BE 127-7.5-40 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-7.5-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port, (1) 7.5mm ID temperature probe port, and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127-7.5 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-7.5 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and 7.5mm temperature probe port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127-40 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127-40 Wye Connector with (2) 22mm OD ports, (1) 15mm ID/22mm OD port and (1) barbed pressure port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 127 Wye Connector
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 127 Wye Connector with (2) 22mm OD ports and (1) 15mm ID/22mm OD port. Fits components of adult ventilator circuits. Reusable.
0
-
BE 125-1TD Disposable Tee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1TD Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Can be used to easily add a monitoring device such as a temperature probe to the breathing circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D. Single Patient Use. Molded of High Density Polyethylene.
0
-
BE 125-1T ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1T Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm I.D. x 15mm I.D./22mm O.D Reusable.
0
-
BE 125-1 ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125-1 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 22mm O.D. x 15mm I.D./22mm O.D Reusable.
0
-
BE 125 ReusableTee Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
The BE 125 Tee Adapter is intended for use in a ventilator, oxygen or BIPAP circuit. Dimensions: 22mm O.D. x 15mm I.D./22mm O.D. x 15mm O.D./22mm O.D Reusable.
0
-
BE 122-30 Flexible Support Arm
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-30 Flexible Support Arm - 30" - (With extension, reaches 44" total length) - Use to support ventilator tubing; Rotates up to 360° and can be locked in place. Adapts to most ventilators by using Flexible Support Arm Brackets. Ventilator tubing is held in place with Flexible Support Arm Tubing Clamps mounted to the Flexible Support Arm. All are manufactured in the USA by Instrumentation Industries, Inc.
0
-
"BE 122-2TSB - 4"" Flexible Support Arm Double Tubing Clamp"
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-2TSB - 4" Flexible Support Arm Double Tubing Clamp holds two ventilator tubes in place when attached to an III "Flexible Support Arm". Made of polypropylene and anodized aluminum with phenolic ball knob. Made in the USA.
0
-
"BE 122-2TB - 8"" Flexible Support Arm Double Tubing Clamp"
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-2TB - 8" Flexible Support Arm Double Tubing Clamp holds two ventilator tubes in place when attached to an III "Flexible Support Arm". Made of polypropylene and anodized aluminum with phenolic ball knob. Made in the USA.
0
-
BE 122-24 Flexible Support Arm
INSTRUMENTATION INDUSTRIES, INCORPORATED
BE 122-24 Flexible Support Arm - 24" - (With extension, reaches 38" total length) - Use to support ventilator tubing; Rotates up to 360° and can be locked in place. Adapts to most ventilators by using Flexible Support Arm Brackets. Ventilator tubing is held in place with Flexible Support Arm Tubing Clamps mounted to the Flexible Support Arm. All are manufactured in the USA by Instrumentation Industries, Inc.
0
-
BE 120-AKW 45 degree Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Specialty Adapter - 22mm ID x 22mm OD Adapter for ventilator circuits/CPAP systems. Molded of polystyrene butadiene. Single Patient Use.
0
-
BE 120-22D Mouthpiece Adapter
INSTRUMENTATION INDUSTRIES, INCORPORATED
Specialty Mouthpiece Adapter with 22mm ID fitting. Molded of polystyrene butadiene. Single Patient Use.