RevMed

BRYDAN MEDICAL HOLDINGS 12610 BRYDAN MEDICAL

Company Name
BRYDAN MEDICAL HOLDINGS
Catalog Number
12610

Description

Aluminum I.V. pole for W/C, adjustable height, for WC -
Have questions, or need more information? Contact Us

Pricing
Summary

Price Not Available
Out of Stock
Interested in this product?
Contact us or login to add to your watchlist.

Related Items

OEC Elite CFD

GE OEC ELITE CFD

GE OEC Elite CFD 31cm Flat Detector Super C-Arm - VAS 15 Software. GE OEC Elite CFD C-Arm 31 cm Flat Detector w/ Bumper VAS 15 Vascular Software, SUPER C Motorized C Refurbished, Calibrated, Ready for Use 31 cm CMOS Flat Detector (CFD) - CMOS - Complementary metal-oxide semiconductor detector - DQE(0): 72% - Active amplification inside pixel for ultra-fast electron mobility - Active Matrix: 1548x1524 pixels - Pixel Pitch: 190.0 um - Nominal resolution (at display): 31 cm: 2.7 lp/mm; 21 cm: 2.8 lp/mm; 15 cm: 2.9 lp/mm - Quad-mode magnification: Live Zoom fluidly from 1 to 4X with no change in dose; Fixed try-mode Mag settings: 31cm/21cm/15cm Workstation Display - 13.6 in Live and Reference Image displayed size - 1 to 1 detail imaging chain from CMOS detector to 4K display resolution - Squircle shaped image retains 100% of image when rotated and no cropped or changed view. - 4K, 32" Ultra high definition (UHD) Color Display - Monitor displays two split screens for equivalent view of two 20in displays - 3840x2160 display resolution - 600 cd/m2 maximum brightness - Touchscreen interface with anti-reflection, anti-fingerprint - Easily position monitor to surgical line of sight with display mount on an articulating arm with five movements What's Included: GE OEC Elite CFD C-Arm, Super C; (REF OEC Elite) Qty: 1 GE Beam Limiting Device; (REF 5455288-03) Qty: 1 GE Laser Aiming Device; (REF 5440087) Qty: 1 GE Image Receptor; (REF 5457729-02) Qty: 1 GE Remote User Interface; (REF 5719003-01) Qty: 1 GE Hand Control OEC ELITE; (REF 5819193); Qty; 1 GE Foot Switch; (REF 1482807); Qty: 1 GE Skin Spacer - Squircular; (REF 5436688-01) Qty: 2
$157,647.06
Equipment
-

MOMENTIS SURGICAL LTD - Anovo Surgeon Console and Anovo Power cable

The AnovoTM Surgical System is a robotic-assisted device intended for use by laparoscopic trained physicians for endoscopic manipulation of tissue, using graspers and electrosurgery devices during single-site laparoscopic gynecologic procedures such as benign hysterectomy and salpingo-oophorectomy through a transvaginal access point. The system composed of Anovo Surgeon Console, two sterile instruments (Anovo Instrument ARMS), bed-mounted Robotic Control Unit (RCU) and Anovo System Accessories (Unit cables, Sterile Drapes, Robotic Control Unit Support System (RCUSS) and Vaginal Access Kit). Anovo Surgeon Console (UDI # 07290018151013) packed with its power cable (UDI # 07290018151037)The Anovo Surgeon Console comprised of Arm Controllers (Joysticks and Thumbsticks), an Adjustable Controllers Stand, a PC with Touch Screen, Manual Release Tool and the Power Adapter, and allowing the operating surgeon to operate the Anovo Instrument Arms. There are two sets of Arm Controllers for the Anovo System: two Thumbsticks and two ARMS Controllers. The ARMS Controllers are enabled only when the system is at “resume” state and allow for the accurate control of the Anovo Instrument ARMS during the surgical procedure. Like the Anovo Instrument Arm, each ARMS Controllers has three joints: wrist, elbow and shoulder, so that each Anovo Instrument ARM moves accordingly to Controller's movement. The surgeon-held Controller handle is above the elbow joint and allows for multiple functionality transitions.
Out of Stock
General & Plastic Surgery

Additional Details

Device Identifier
00853301008165
Is RX
No
Is Over the Counter
No
Requires Sterilization
No
Is Sterile
No
Is Single Use
No

Barcode Mapping

Unit of MeasurementEachesGTIN
Each100853301008165