RevMed

Paragon Vision Sciences, Inc. 900 Vial Assembly

Company Name
Paragon Vision Sciences, Inc.
Catalog Number
900
UOMs
  • Each
  • Package of 1,000

Description

Contact lens vial with cap and gasket/clawThe finished assemblies can be made with variation in the color of the cap and the insertion of a gasket or a claw. Additionally, the claw has three distinct sizes, Small (S), Large (L), and Extra Large (X).
Have questions, or need more information? Contact Us

Pricing
Summary

Price Not Available
Out of Stock
Interested in this product?
Contact us or login to add to your watchlist.

Related Items

See Description

Smith & Nephew Arthroscopy Tower

Multiple Used Smith and Nephew Arthroscopy Towers in good condition. CAN BE SOLD SEPARATELY These Smith and Nephew Arthroscopy Towers are a comprehensive system designed for arthroscopic surgeries, providing high-quality imaging and efficient management of surgical procedures. Key components of the system include: LCD Monitor (Model: LMD-X310MD, SN: 8000251): This monitor offers crisp and clear display capabilities, essential for viewing real-time surgical images and videos during procedures. Its high-resolution screen ensures optimal visualization for surgical precision. S&N LENS Integrated System (REF: 72204354, SN: EEI063): This integrated system includes advanced lenses optimized for arthroscopic procedures, enhancing clarity and detail in imaging. It contributes to improved visualization of the surgical site, aiding in accurate diagnosis and treatment. S&N 660HD-E Image Management System (REF: 72204668, SN: EEO1193): The image management system plays a vital role in storing, organizing, and retrieving surgical images and videos. It offers streamlined workflow management, allowing surgeons to efficiently access and review patient data during and after procedures. Sony AC Adaptor (Model: AC-300MD, SN: 6401H617): The AC adaptor provides reliable power supply to the various components of the arthroscopy tower, ensuring uninterrupted operation throughout surgical procedures. Its compatibility with the system components enhances overall reliability and performance. Sony Digital Color Printer (Model: UP-DR80MD, SN: 731682): This digital color printer is utilized for printing high-quality images captured during arthroscopic surgeries. It offers fast and efficient printing capabilities, enabling surgeons to create detailed documentation of procedures for reference and patient records.
$45,000.00
Equipment
800070

THD SPA 800070 THD Revolution

THD Slide is specifically designed to be immediately used with the THD Evolution/Revolution doppler de-arterialiser. THD Slide is a specifically designed anoscope/proctoscope for improving the THD procedure while treating the higher grades of the haemorrhoidal disease. The specific shape of the anoscope/proctoscope, which includes a sliding part, allows to perform the ligation and the prolapse reduction with the same device and reduces the disease for the patient and speeds up the procedure. The peculiar shape of the anoscope/proctoscope, with the sliding probe holder, allows to perform ligation and prolapse reduction with a single tool. The THD Slide anoscope/proctoscope is made in a clear, medical grade, plastic which allows, with the use of the shaped fibre optic tip, a perfect lightning of the operative field. The particular THD anoscope/proctoscope is designed to maintain the right strain into the anal cavity during the treatment and it presents a lodge for the THD needle holder. The supplied doppler probe lodges into the anoscope/proctosocpe and is in contact with the anal mucosa for an accurate detection of the haemorrhoidal arteries. The THD Slide One box contains 10 individually packed disposable doppler probes, which can be immediately be used without preventive cleaning and sterilisation. The box also con-tains 10 absorbable sutures packs (6 sutures each pack) and 10 THD Spon-Anal haemostatic sponges
$214.31
Radiology
DPM-6

Mindray DPM6 Patient Monitor

Several used DPM6 Patient Monitors, each equipped with a broad array of patient monitoring capabilities suitable for mid and high acuity departments, are available. Incorporating a 12.1" touchscreen display, these monitors are designed to meet the stringent demands of both ICU and OR settings. All units are in good condition and maintain functionality to ensure reliable performance in critical medical environments. Key Features and Benefits: * 12.1" High-Resolution Touchscreen: Provides a clear and responsive interface for swift navigation and operation. * Streamlined Touchscreen Interface: Enables quick access to monitor functions, ensuring efficient operation. * 48-Hour Full Disclosure Waveform Review: Offers extensive review capabilities for comprehensive waveform analysis. * NIBP Recall for 1,000 Measurements: Facilitates easy access to a large pool of recent blood pressure measurements. * Alarm Event Review: Stores up to 100 physiological/arrhythmia alarm episodes for thorough analysis. * Connectivity Options: Links seamlessly to the DPM CS central station or Panorama® Patient Monitoring Network, enhancing data sharing and accessibility. * Integration with Nurse Call Systems: Allows direct interfacing with nurse call systems for streamlined communication. * Expandable Functionality: Equipped with 5 built-in module slots and an 8-slot external module rack for added versatility and customization. * Base Tests: Includes 3/5-lead ECG, non-invasive blood pressure, SpO2, pulse rate, respiration, dual-channel invasive blood pressure, and dual-channel temperature capabilities.
$2,500.00
Equipment
PLEE45A

Ethicon Endo-Surgery PLEE45A ECHELON FLEX

The ECHELON FLEX Powered Plus Articulating Endoscopic Linear Cutters are sterile, single patient use instruments that simultaneouslycut and staple tissue. There are six staggered rows of staples, three on either side of the cut line. The ECHELON FLEX 45 Powered Plusinstruments have a staple line that is approximately 45 mm long and a cut line that is approximately 42 mm long. The shaft can rotate freelyin both directions and an articulation mechanism enables the distal portion of the shaft to pivot to facilitate lateral access to the operativesite.The instruments are packaged with a primary lithium battery pack that must be installed prior to use. There are specific requirements fordisposing of the battery pack. Refer to the Battery Pack Disposal section.The instruments are packaged without a reload and must be loaded prior to use. A staple retaining cap on the reload protects the staple legpoints during shipping and transportation. The instruments’ lock-out feature is designed to prevent a used or improperly installed reloadfrom being refired or an instrument from being fired without a reload.
$175.93
General & Plastic Surgery

Additional Details

Device Identifier
B222900
Is RX
No
Is Over the Counter
No
Requires Sterilization
No
Is Sterile
No
Is Single Use
No

Barcode Mapping

Unit of MeasurementEachesGTIN
Each1B2229009
Package of 1,0001000B222900