Radiology
Main Filters
Radiology
| ACUTUS MEDICAL, INC. | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| 800255 | 0 | - | ||
| 800405 | 0 | - | ||
| 800530 | 0 | - | ||
| 800531 | 0 | - | ||
| 800601 | 0 | - | ||
| 800604 | 0 | - | ||
| 800605 | 0 | - | ||
| 900000 | 0 | - | ||
| 900009 | 0 | - | ||
| 900100 | 0 | - | ||
| BRONCUS MEDICAL INC. | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| 10009-1 | 0 | - | ||
| 10009-2 | 0 | - | ||
| 30005 | 0 | - | ||
| 30009 | 0 | - | ||
| 40005 | 0 | - | ||
| 40009 | 0 | - | ||
| Digisonics Inc | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| 3.8 | 0 | - | ||
| 4.0 | 0 | - | ||
| 4.8 | 0 | - | ||
| 4.9 | 0 | - | ||
| FAXITRON BIOPTICS, LLC | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| BioVision 10x15 | 0 | - | ||
| CoreVision 5x10 | 0 | - | ||
| NEOCOIL, LLC | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| 62 | 0 | - | ||
| 63 | 0 | - | ||
| 64 | 0 | - | ||
| 65 | 0 | - | ||
| 71 | 0 | - | ||
| 72 | 0 | - | ||
| 73 | 0 | - | ||
| 74 | 0 | - | ||
| 75 | 0 | - | ||
| 76 | 0 | - | ||
| 77 | 0 | - | ||
| 78 | 0 | - | ||
| 79 | 0 | - | ||
| 80 | 0 | - | ||
| 82 | 0 | - | ||
| 89 | 0 | - | ||
| NC143000 | 0 | - | ||
| NC143001 | 0 | - | ||
| NC143002 | 0 | - | ||
| NC143003 | 0 | - | ||
| NC143005 | 0 | - | ||
| NC143202 | 0 | - | ||
| NC143203 | 0 | - | ||
| VARIAN MEDICAL SYSTEMS UK HOLDINGS LIMITED | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| AL19004-000 | 0 | - | ||
| AL19004-001 | 0 | - | ||
| VARIAN MEDICAL SYSTEMS, INC. | ||||
| CATALOG # | QTY | PRICE | DESCRIPTION | |
| 13.7 | 0 | - | ||
| TM60010004 | 0 | - | ||
| TM64001000 | 0 | - | ||
75,147 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
Faxitron
FAXITRON BIOPTICS, LLC
Mobile digital specimen x-ray system with 10x15 cm imager for the examination of Biopsy excisions.
0
-
Faxitron
FAXITRON BIOPTICS, LLC
Stationary digital specimen x-ray system with 5x10 cm imager intended for the examination of Core Biopsy excisions.
0
-
Archimedes Access Key, 10-pack
BRONCUS MEDICAL INC.
Archimedes Planning Software is software installed on a laptop computer used for planning bronchoscopic procedures. The Planning program provides a planning system to select the region of interest and preview virtual paths to the region of interest through both airways and lung tissue.
0
-
Archimedes Access Key
BRONCUS MEDICAL INC.
Archimedes Planning Software is software installed on a laptop computer used for planning bronchoscopic procedures. The Planning program provides a planning system to select the region of interest and preview virtual paths to the region of interest through both airways and lung tissue.
0
-
LungPoint VBN System, V3.2
BRONCUS MEDICAL INC.
LungPoint VBN Software is software installed on a desktop computer used to plan procedures and navigate to targets in the lung. The LungPoint Procedure Program offers real-time navigation guidance for use during the bronchoscopy procedure. The software allows visualization of the bronchial tree; helps guide the tools in or adjacent to the bronchial tree; allows visualization of a predefined target in lung tissue; and assists with placement of markers into soft lung tissue to guide radiosurgery and thoracic surgery.
0
-
LungPoint Planning System, v3.2
BRONCUS MEDICAL INC.
LungPoint Planning Software is software installed on a laptop computer used for planning bronchoscopic procedures. The Planning program provides a planning system to select the region of interest and preview virtual paths to the region of interest through both airways and lung tissue.
0
-
Archimedes Planning System
BRONCUS MEDICAL INC.
Archimedes Planning Software is software installed on a laptop computer used for planning bronchoscopic procedures. The Planning program provides a planning system to select the region of interest and preview virtual paths on the computer or printed plan to the region of interest through both airways and lung tissue.
0
-
Archimedes System
BRONCUS MEDICAL INC.
Archimedes software is installed on a desktop computer used to plan procedures and navigate to targets in the lung. The Procedure Module offers real-time navigation guidance for use during the bronchoscopy procedure. The Software provides the option to segment previously acquired CT or other DICOM data sets and overlay and register these segmented data sets onto live fluoroscopic X-ray images. The software allows visualization of the bronchial tree; helps guide the tools in or adjacent to the bronchial tree; allows visualization of a predefined target in lung tissue; and assists with placement of markers into soft lung tissue to guide radiosurgery and thoracic surgery.
0
-
16ch Shoulder Coil, Replacement Pad Kit (FRU)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
1.5T 16ch Shoulder Coil (FRU)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
3.0T 16ch Shoulder Coil (FRU)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
1.5T 16ch Shoulder Coil (System)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
3.0T 16ch Shoulder Coil (System)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
1.5T 16ch Shoulder Coil (Device)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniformcoverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receivesmagnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magneticfield applied by the MRI scanner at specified timings. The received signals are amplified before being transferred to the MRIscanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy. During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
3.0T 16ch Shoulder Coil (Device)
NEOCOIL, LLC
The 16ch Shoulder Coil is a receive-only phased array RF coil designed for optimum signal-to-noise ratio (SNR) and uniform coverage of the shoulder anatomy for use with GE Healthcare Magnetic Resonance Imaging (MRI) scanners. The coil receives magnetic resonance signals generated in hydrogen nuclei (protons) in the shoulder while blocking the high-frequency magnetic field applied by the MRI scanner at specified timings.The received signals are amplified before being transferred to the MRI scanner through the coil’s system cable. The amplified signals are processed into tomographic images of the shoulder anatomy by the MRI scanner. Images are typically generated as axial, sagittal, coronal oblique slices and include coverage of the Humerus, Humeral Head, Labrum, Labral Tear, Glenoid, Scapula, Clavicle, and Rotator Cuff regions of the shoulder anatomy.During a shoulder MRI exam, the patient lays in the supine position on the MRI scanner table. The rigid Posterior Array is positioned beneath the patient’s affected shoulder. The flexible Anterior Array is positioned on top of the patient’s affected shoulder. The 16ch Shoulder Posterior Housing Pad and 16ch Shoulder Pad provided with the coil promote patient comfort and facilitate patient positioning. Table Straps provided with the MRI scanner may be used to minimize unintended patient movement during the exam.
0
-
1.5T 16Ch Breast Coil
NEOCOIL, LLC
The NeoCoil 1.5T 16ch Breast Coil is a phased array coil for imaging structures of the breast, axilla and chest wall. The 1.5T 16ch Breast Coil is a three part receive-only coil designed to provide high resolution imaging. The 1.5T 16ch Breast Coil includes a coil support structure, patient support structure, biopsy components and comfort pads.
0
-
3.0T 16ch Breast Coil
NEOCOIL, LLC
The NeoCoil 3.0T 16ch Breast Coil is a phased array coil for imaging structures of the breast, axilla and chest wall. The 3.0T 16ch Breast Coil is a three part receive-only coil designed to provide high resolution imaging. The.3.0T 16ch Breast Coil includes a coil support structure, patient support structure, biopsy components and comfort pads.
0
-
Technologist Console Interface
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Router Assembly
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Scan Room Module
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Sentinel P2 Audio Interface Module
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Sentinel P1 Audio Interface Module
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Sentinel S2 Audio Interface
NEOCOIL, LLC
The NeoCoil Wireless Audio System is intended to provide entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The Wireless Audio System is intended to be used by healthcare professionals.The NeoCoil Wireless Audio System is a modular system comprised of wireless patient headphones, a remote audio data source unit, and communications infrastructure.
0
-
Pediatric SPEEDER Stabilizer Kit
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi
0
-
Siemens audio module
NEOCOIL, LLC
The NeoCoil Patient Communication and Entertainment (PCE) System is intended to provide audio entertainment and facilitate communications between the patient and the operator in a Magnetic Resonance Imaging (MRI) scanner environment. The PCE System is intended to be used by healthcare professionals.
0
-
16Ch Flex SPEEDER Pad Kit
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coi
0
-
Family Pack, foam kit
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
0
-
General Purpose Support strap
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
0
-
General Purpose Support pad
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
0
-
Preamp Box Foam Sleeve
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
0
-
Flex Coils Pediatric Stabilizer System
NEOCOIL, LLC
These accessory immobilization devices are intended for use in conjunction with a NeoCoil Flex Coil for patient comfort and stabilization. Please refer to the device labeling for intended use of your particular NeoCoil Flex Coil.
