TOBY ORTHOPAEDICS
Main Filters
TOBY ORTHOPAEDICS
TOBY ORTHOPAEDICS | ||||
CATALOG # | QTY | PRICE | DESCRIPTION | |
TO-35-T10-CLS-10 | 0 | - | ||
TO-35-T10-CS-10 | 0 | - | ||
TO-35-T10-CS-12 | 0 | - | ||
TO-35-T10-CS-14 | 0 | - | ||
TO-35-T10-CS-16 | 0 | - | ||
TO-35-T10-CS-18 | 0 | - | ||
TO-35-T10-CS-20 | 0 | - | ||
TO-35-T10-CS-22 | 0 | - | ||
TO-35-T10-CS-24 | 0 | - | ||
TO-35-T10-CS-26 | 0 | - | ||
TO-35-T10-CS-28 | 0 | - | ||
TO-35-T10-CS-30 | 0 | - | ||
TO-35-T10-CS-32 | 0 | - | ||
TO-35-T10-CS-34 | 0 | - | ||
TO-52-CP-30 | 0 | - | ||
TO-52-CP-35 | 0 | - | ||
TO-52-CP-40 | 0 | - | ||
TO-52-CP-45 | 0 | - | ||
TO-52-CP-50 | 0 | - | ||
TO-CDB40-130 | 0 | - | ||
TO-CLP-LBP-174 | 0 | - | ||
TO-CLP-LBP-200 | 0 | - | ||
TO-CLP-LBP-201 | 0 | - | ||
TO-DB20-110 | 0 | - | ||
TO-DB20-160 | 0 | - | ||
TO-DB25-160 | 0 | - | ||
TO-DB40-160 | 0 | - | ||
TO-DG-RING-31 | 0 | - | ||
TO-DG-RING-50 | 0 | - | ||
TO-DRI-M-CQCH | 0 | - | ||
TO-KW-16-230 | 0 | - | ||
TO-LBP-070 | 0 | - | ||
TO-LBP-096 | 0 | - | ||
TO-LBP-122 | 0 | - | ||
TO-LBP-148 | 0 | - | ||
TO-LBP-174 | 0 | - | ||
TO-LBP-200 | 0 | - | ||
TO-LBP-226 | 0 | - | ||
TO-LBP-252 | 0 | - | ||
TO-LBP-278 | 0 | - | ||
TO-LP-LBP-070 | 0 | - | ||
TO-LP-LBP-096 | 0 | - | ||
TO-LP-LBP-122 | 0 | - | ||
TO-LP-LBP-148 | 0 | - | ||
TO-PHP-L120 | 0 | - | ||
TO-PHP-R120 | 0 | - | ||
TO-WOLF-INS-ST | 0 | - | ||
TO-WOLF-LP-ST | 0 | - | ||
TO-WOLF-ST | 0 | - | ||
TO-WOLF-STL | 0 | - |
153 Results
Results Per Page
- 50
- 100
- 250
Catalog #
AvailableQty
Starting At
Name
Company Name
Description
0
-
3.5mm T10 Drive Cortical Locking Screw, 10mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws (torx T-10 head) are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 45mm.
0
-
3.5mm T10 Drive Cortical Screw, 34mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 32mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 30mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 28mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 26mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 24mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 22mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 20mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 18mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 16mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 14mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 12mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
3.5mm T10 Drive Cortical Screw, 10mm
TOBY ORTHOPAEDICS
The titanium alloy cortical (non-locking) torx T-10 head screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 10mm to 34mm.
0
-
5.2mm Cannulated Post, 30mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
0
-
5.2mm Cannulated Post, 35mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
0
-
5.2mm Cannulated Post, 40mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
0
-
5.2mm Cannulated Post, 45mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
0
-
5.2mm Cannulated Post, 50mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm. They are cannulated i.e a K-wire can pass through the post longitudinally.
0
-
PANTERA PLATE, RIGHT, 120mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, LEFT, 120mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
Cannulated Universal Quick Connect Handle
TOBY ORTHOPAEDICS
Drivers are of various tips and handle geometry and are made of stainless steel that is heat treated and passivated. Driver assembly handles are made from machined Radel.
0
-
1.6mm K-Wire x 230mm
TOBY ORTHOPAEDICS
K-wires are stainless steel wires of various lengths and diameters.
0
-
WOLF® Low Profile Plate Sterilization Tray
TOBY ORTHOPAEDICS
Sterilization Tray for WOLF Implants and Screw Caddy/Caddies.
0
-
WOLF® Plate Sterilization Tray
TOBY ORTHOPAEDICS
Sterilization Tray for WOLF Implants and Screw Caddy/Caddies.
0
-
WOLF® Sterilization Tray Lid
TOBY ORTHOPAEDICS
Sterilization Tray Lid for WOLF Implants, Instruments and Screw Caddy/Caddies.
0
-
WOLF® Instrument Sterilization Tray
TOBY ORTHOPAEDICS
Sterilization Tray for WOLF Instruments and Screw Caddy/Caddies.
0
-
WOLF Curved Low Profile Plate, 226mm, 17 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Curved Low Profile Plate, 200mm, 15 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Curved Low Profile Plate, 174mm, 13 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Low Profile Plate, 148mm, 11 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Low Profile Plate, 122mm, 9 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Low Profile Plate, 96mm, 7 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Low Profile Plate, 70mm, 5 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 278mm, 21 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 252mm, 19 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 226mm, 17 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 200mm, 15 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 174mm, 13 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyse
0
-
WOLF Plate, 148mm, 11 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 122mm, 9 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 96mm, 7 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
WOLF Plate, 70mm, 5 Hole
TOBY ORTHOPAEDICS
The long bone plates are made of titanium alloy, are provided in standard and low profile thicknesses, and also standard and curved configurations. The plates are contoured to provide a close fit with the anatomy of the radius, ulna and humerus bones. The plates are provided with multiple hole configurations and lengths to accommodate fixation cases for a variety of upper extremity diaphyses.
0
-
4.0mm Cannulated Drill Bit X 130mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
2.0mm Drill Bit X 160mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
4.0mm Drill Bit X 160mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
2.5mm Drill Bit X 160mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
2.0mm Drill Bit X 110mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.