RevMed
Home/Brands/TOBY ORTHOPAEDICS

TOBY ORTHOPAEDICS

153 Results
Results Per Page
  • 50
  • 100
  • 250
Catalog #
Qty
Starting At
Name
Company Name
Description
0
-
Precision Square Driver Retrofit Bracket
TOBY ORTHOPAEDICS
Component of Sterilization Tray.
0
-
PANTERA PLATE, LEFT, 220mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, RIGHT, 220mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, LEFT, 180mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, RIGHT, 180mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, LEFT, 160mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, RIGHT, 160mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
3.5mm Cortical Screw, 34mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 32mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
5.2mm Post, 30mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm.
0
-
Precision Square Driver
TOBY ORTHOPAEDICS
Drivers are of various tips and handle geometry and are made of stainless steel that is heat treated and passivated. Driver assembly handles are made from machined Radel.
0
-
4.0mm Drill Bit X 110mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
1.6mm K-Wire X 130mm
TOBY ORTHOPAEDICS
K-wires are stainless steel wires of various lengths and diameters.
0
-
2.5mm/3.5mm Drill Guide
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Pantera Sterilization Tray
TOBY ORTHOPAEDICS
Sterilization Tray for Pantera Implants, Instruments and Screw Caddy/Caddies.
0
-
Pantera Screw Caddy
TOBY ORTHOPAEDICS
Caddies are assemblies of various layouts that hold screws, and post of various lengths and types. The base is of machined Polypropylene, and lids of Smoked Radel.
0
-
Locking Screw Drill Guide, 28mm
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Post Drill Guide Sleeve, 28mm
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Post Drill Guide, 28mm
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Cross Element Guide Sleeve
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Cross Element Guide Retainer
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Cross Element Guide
TOBY ORTHOPAEDICS
Guides are stainless steel parts of various designs that allow various drill diameters. Some guides are laser weld assemblies with a handle, and others are threaded to screw into plates.
0
-
Depth Gauge, 50mm
TOBY ORTHOPAEDICS
Depth Gauges are assemblies made from stainless steel parts, with an outer housing, and a scaled slide with tip to measure depth of screw holes. Some assemblies use a Silicone O-ring for friction hold.
0
-
Square Driver
TOBY ORTHOPAEDICS
Drivers are of various tips and handle geometry and are made of stainless steel that is heat treated and passivated. Driver assembly handles are made from machined Radel.
0
-
Cruciform Driver
TOBY ORTHOPAEDICS
Drivers are of various tips and handle geometry and are made of stainless steel that is heat treated and passivated. Driver assembly handles are made from machined Radel.
0
-
2.5mm Hex Driver
TOBY ORTHOPAEDICS
Drivers are of various tips and handle geometry and are made of stainless steel that is heat treated and passivated. Driver assembly handles are made from machined Radel.
0
-
2.5mm Drill Bit X 110mm
TOBY ORTHOPAEDICS
Drill Bits are of various diameters and lengths, and are made of Stainless Steel, heat-treated and passivated. Some drill bits have laser marked scales to show depth of drill.
0
-
PANTERA PLATE, RIGHT, 83mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, LEFT, 83mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
0
-
PANTERA PLATE, RIGHT, 73mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clip.
0
-
PANTERA PLATE, LEFT, 73mm
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips
0
-
5.2mm Post, 50mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm.
0
-
5.2mm Post, 45mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm.
0
-
5.2mm Post, 40mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm.
0
-
5.2mm Post, 35mm
TOBY ORTHOPAEDICS
Titanium alloy posts are used to affix the proximal end of the plate to the proximal end of the humerus. With the aid of fixtures, the posts have the ability to have cross elements inserted perpendicular to the axis of the cortical thread of the post. The head of the post is a threaded locking configuration that accepts an expansion cap screw. The posts are 5.25mm in diameter and are available in 5 lengths ranging from 30mm to 50mm.
0
-
2.0mm Cross Element, 35mm
TOBY ORTHOPAEDICS
Titanium alloy cross elements are designed to provide additional support to the humeral head by entering the posts perpendicular to the axis of the cortical thread of the posts.
0
-
2.0mm Cross Element, 30mm
TOBY ORTHOPAEDICS
Titanium alloy cross elements are designed to provide additional support to the humeral head by entering the posts perpendicular to the axis of the cortical thread of the posts.
0
-
2.0mm Cross Element, 25mm
TOBY ORTHOPAEDICS
Titanium alloy cross elements are designed to provide additional support to the humeral head by entering the posts perpendicular to the axis of the cortical thread of the posts.
0
-
3.5mm Cortical Screw, 30mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 28mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 26mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 24mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 22mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Screw, 20mm
TOBY ORTHOPAEDICS
The titanium alloy cortical screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 34mm.
0
-
3.5mm Cortical Locking Screw, 45mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.
0
-
3.5mm Cortical Locking Screw, 40mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.
0
-
3.5mm Cortical Locking Screw, 35mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.
0
-
3.5mm Cortical Locking Screw, 30mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.
0
-
3.5mm Cortical Locking Screw, 28mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.
0
-
3.5mm Cortical Locking Screw, 26mm
TOBY ORTHOPAEDICS
The titanium alloy cortical locking screws are used to affix the plate to the humerus. The screws are 3.5mm diameter and are available in various lengths from 20mm to 45mm.